background image

RWL-1-SL Operating Manual.doc 

 

2021-12-20 

 

2/13 

 

D

ESIGN AND APPLICATION

 

RWL-1-SL lock enables read-in access control based on MIFARE proximity cards - based on the card 

numbers stored in its memory, the lock decides autonomously if the access can be granted.  

The RWL-1-SL lock consists of two escutcheons with handles and mortise lock. Card reader is installed 
in the external escutcheon while the battery pack is installed in the internal escutcheon. The internal 

handle is permanently coupled with deadbolt thus the door can be always opened from the inside 
regardless of proximity card and batteries charge level. The external handle is separated from the 

deadbolt and moves freely. When the access is granted the electronic module couples the external 
handle with deadbolt and latch to enable door opening. When the door is closed then the deadbolt is 
relocked automatically in order to protect door against unauthorized opening. The RWL-1-SL lock can 

be optionally equipped with door cylinder and then be opened from the outside with traditional metal 
key. The RWL-1-SL is equipped with knob switch position detector. The lock is supplied with 4 pcs of 

AA batteries. Low battery level can be signalled locally. The batteries enable two year operation for 
average 10 card readings per day. 

Depending on door opening direction and handle location on the door leaf the adequate type of RWL-

1-SL lock must be applied.  

Version 

Description 

RWL-1-SL-LI 

Left hand door 

RWL-1-SL-RI 

Right hand door 

RWL-1-SL-LO 

Left hand reverse door 

RWL-1-SL-RO 

Right hand reverse door 

 

 

Fig 1. RWL-1-SL lock in inward opening doors while standing outside 

Содержание RWL-1-SL

Страница 1: ...Roger Access Control System RWL 1 SL Standalone Door Lock Operating Manual Firmware version 1 1 Document version Rev A ...

Страница 2: ... electronic module couples the external handle with deadbolt and latch to enable door opening When the door is closed then the deadbolt is relocked automatically in order to protect door against unauthorized opening The RWL 1 SL lock can be optionally equipped with door cylinder and then be opened from the outside with traditional metal key The RWL 1 SL is equipped with knob switch position detect...

Страница 3: ...led room The escutcheon includes card reader A and hole for door cylinder G which can be used for emergency door opening with mechanical key The electronic module which is located inside the escutcheon includes service pins B and programming pins C Wires with larger plug D are used to connect the electronic module with mortise lock and wires with smaller plug E are used to connect the module with ...

Страница 4: ...its status using cable with connector I The connector can be plugged into socket K at the mortise lock The door can be locked with the knob switch and then it cannot be opened from the outside using proximity card When the handle is twisted then the knob reverts to normal position The internal escutcheon includes also battery pack J In order to replace batteries unscrew two top bolts and pull the ...

Страница 5: ...tronic module External handle is coupled momentary whenever access is granted When the RWL 1 SL is operated in Office mode then external handle is coupled permanently Handle spacing i e distance from handle to cylinder in the mortise lock equals to 72mm Fig 6 Mortise lock Door cylinder RWL 1 SL lock is adapted to door cylinder installation Such cylinder enables emergency door opening from the outs...

Страница 6: ...alone Access Control The lock grants access for cards stored in its memory Up to 100 cards can be defined and stored in lock s memory Each card can be authorised for momentary door opening option Normal access and or to open the door for unlimited time option Office access If the card is authorized for Normal access then it opens the lock for the time specified by the parameter Lock pulse If the c...

Страница 7: ...red with 2 programming cards ADD card and DEL card Lock pulse by default is set to 2 sec while built in RFID reader is configured to read card serial numbers CSN Factory cards Label Name Authorization ADD ADD programming card New card adding to the lock DEL DEL programming card Card deleting from the lock Configuration recovery from the lock In some circumstances it might be required to recover th...

Страница 8: ...d to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are generated by lock and then you can continue with more cards programming Example Programming of user with Office access Read ADD programming card twice Read first card to program user s Main card Read second card to program user s Backup card Wait till 3 acoustic beeps are generated by lock a...

Страница 9: ... to configure the lock using computer and RogerVDM software 1 Place jumper on MEM pins 2 Connect the lock to RUD 1 interface using dedicated cable fig 6 3 Short RST pins for a moment preferably by placing and removing jumper Orange LED SYSTEM shall pulsate 4 In RogerVDM select Device New and then select type of device RWL 1 SL and serial COM port with RUD 1 interface 5 Select required settings 6 M...

Страница 10: ...onfirmed with short acoustic beep Default value Yes LED SYSTEM pulsing when card close to the reader When option is set then orange LED SYSTEM pulses whenever card is detected near the reader Default value No Battery low level signalisation When option is set then lock signals low battery level by orange LED SYSTEM indicator pulsing and series of 5 acoustic beeps after card reading Default value Y...

Страница 11: ... value 0 Application ID The parameter Application ID AID is located in card s MAD sector and it specifies the sector where programmable card number PCN is stored if the Sector type see above is configured as MAD Default value 5156 Roger AID Block ID The parameter specifies the block number where programmable card number PCN is stored in a particular sector of card s memory For sectors 0 31 blocks ...

Страница 12: ...installation make sure that door cylinder is long enough Lock installation Make holes in door using drilling template In case of non rebated door it might be necessary to use metal plate Both drilling template and metal plate are included in the factory new set Install mortise lock in such a way that marks which specify proper location of handle pin will be aligned fig 6 Lead K and L groups of wir...

Страница 13: ... of the product This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company o...

Отзывы: