Simple Stand-alone Mode
DTA lines are used as standard I/O lines.
04
OFFLINE Mode
Full Stand-alone Mode
The reader operates as a stand-alone unit, its CLK and
DTA lines are used for communication with a remote XM-
2 I/O module set to address ID=5 and (optionally) with
an auxiliary PRT reader set to address ID=0.
00
ONLINE Mode
RACS Communication Interface
Address ID=0
01
ONLINE Mode
RACS Communication Interface
Address ID=1
02
ONLINE Mode
RACS Communication Interface
Address ID=2
03
ONLINE Mode
RACS Communication Interface
Address ID=3
The reader operates as a unit controlled by a host. This
host-controlled mode requires the reader to be wired to a
PR series access control unit (ACU).
20
ONLINE Mode
MAGSTRIPE
Communication Interface
The reader operates as a unit controlled by a host. This
host-controlled mode requires the reader to be wired to a
master ACU that requires Magstripe data format.
40
ONLINE Mode
26 bit WIEGAND
Communication Interface
60
ONLINE Mode
34 bit WIEGAND
Communication Interface
50
ONLINE Mode
42 bit WIEGAND
Communication Interface
70
ONLINE Mode
66 bit WIEGAND
Communication Interface
The reader operates as a unit controlled by a host. This
host-controlled mode requires the reader to be wired to a
master ACU that requires 26/34/42/66 bit Wiegand data
format.
Note: For details how to select the required
Reader Operating Mode
see section 5.1.
Offline mode
Wire
Color
Label
Simple Stand-alone
mode
Full Stand-alone
mode
Online mode
(unit connected to host ACU)
Red
+12V
Supply input plus.
Blue
GND
Supply input minus.
Green
CLK
Can be configured as
an input or output.
CLOCK
communication line.
DATA 0 line for
Wiegand
formats
CLOCK for
Magstripe
and RACS
formats.
Brown
DTA
Can be configured as
an input or output.
DATA
communication line.
DATA 1 line for
Wiegand
formats
DATA for
Magstripe
and RACS
formats.
Yellow
IN1
Input line, can be configured to several
available functions).
In
Wiegand
and
Magstripe
formats,
the IN1 line activated by shorting it
with the supply minus. When IN1 is
triggered it turns the LED OPEN to
on and also activates acoustic signal
on the internal buzzer.
Grey
White
TAMP
Isolated, tamper switch contacts, when case is closed contacts are shorted.
Pink
NC
Not used (reserved for further use)
Shield
None
Cable shield is internally connected with supply minus (GND)
Содержание PRT62
Страница 1: ...Installation and Programming Guide PRT62 v1 1 Outdoor Access Control Terminal Firmware v74 7 ...
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ... This page intentionally left blank ...
Страница 28: ......
Страница 31: ...Notes No Fault description filled out by the customer Date of repair filled out by the service 1 2 3 4 5 ...