PRT62 v1.1 fv74 EN Rev.E.DOC
10/25/2007
10
5
P
R O G R A M M I N G
Before the PRT62 reader unit can start operation, it must be configured to adequate
Reader Operation Mode
.
If the unit is set for any of the ONLINE operating modes, it does not require any further programming. If it is
set for
Stand-alone Operation Mode
(OFFLINE), an installer will have to program two special cards for it,
these are MASTER and INSTALLER cards, and then enter
Installer Programming Mode
and make a final
settings required by individual installation. The programming of user cards can be done in
User Programming
Mode
either by an installer or by an end user.
If the unit has not been properly prepared for operation, it may produce the following indications:
No acoustic signals and the LED SYSTEM is ON – microprocessor memory error, the unit must be
reloaded with the firmware to correct the problem.
Short beeps (0.2s) separated by 0.2s pause and the LED SYSTEM LED in ON –
Reader Operating
Mode
has not yet been programmed.
Long beeps (2s) separated by 2s pause and the LED SYSTEM is ON – the data memory is corrupted or
MASTER and INSTALLER cards have not yet been programmed.
The PRT62 unit can be programmed manually either in
Installer Programming Mode
or in
User
Programming Mode,
always using the adequate
Programming Card
: use your
MASTER
card when in
User
Programming Mode
or use your
INSTALLER
card when in
Installer Programming Mode
.
The PRT62 reader can be programmed by multiple reading of the suitable
Programming Card
. The
programming sequences consist of series of digits (0, 1…9) and special marks (* and #) and so, to simulate a
[N] digit read your Programming Card N times (simply present it to the reader and take it back) and then wait
2..3 seconds for the reader to generate a special acoustic signal (
♪
♪
) — this is a prompt indicating that the
reader has successfully accepted the series of your card readings as an entry of a single digit or mark and is
now ready for the next step of the programming procedure. Here is how to program single digit(mark) on
PRT62 reader:
Programmed digit or mark
Your action
[1]
Read 1 time your valid Programming Card.
[2]
Read 2 times your valid Programming Card.
[3]
Read 3 times your valid Programming Card.
[4]
Read 4 times your valid Programming Card.
[5]
Read 5 times your valid Programming Card.
[6]
Read 6 times your valid Programming Card.
[7]
Read 7 times your valid Programming Card.
[8]
Read 8 times your valid Programming Card.
[9]
Read 9 times your valid Programming Card.
[0]
Read 10 times your valid Programming Card.
[*]
Read 11 times your valid Programming Card.
[#]
Read 12 times your valid Programming Card.
Notes: The programming of a reader can be done on a primary reader unit only. This rule is valid to both User
and Installer programming modes.
5.1
Setting Reader Operating Mode
The PRT62 reader provides two main modes of operation: ONLINE and OFFLINE (stand-alone). It also offers
several other options which may modify those modes. To select proper operating mode you have to program
the adequate control code to a reader. The control code consist of two digits (marked as D1 and D2). For D1
and D2 coding details see table 1. The reader operating mode can be changed whenever required.
To configure operating mode for the PRT62 reader follow these steps:
Power down the unit.
Remove all connections from DTA and IN1 lines.
Connect DTA to IN1.
Содержание PRT62
Страница 1: ...Installation and Programming Guide PRT62 v1 1 Outdoor Access Control Terminal Firmware v74 7 ...
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ... This page intentionally left blank ...
Страница 28: ......
Страница 31: ...Notes No Fault description filled out by the customer Date of repair filled out by the service 1 2 3 4 5 ...