PRTxxLT series readers Operating Manual.doc
2019-01-29
8/17
*
A
1010
#
B
1011
4 .
I
N S T A L L A T I O N
G
U I D E L I N E S
Reader should be installed in such a way to ensure physical access to the connection cable
and/or screw terminals.
A new factory delivered unit is configured for
RACS address ID=0
The reader should be mounted near the supervised door on a vertical piece of supporting
structure
Disconnect power supply before making any electrical connections
Be aware that when installing the reader directly on the metal type surface card reading
distance will deteriorate
For installations on a metal surface you can place a non-metallic 10 mm thick spacer (a
plastic/plaster plate etc.) between the reader and the supporting structure
For installations with two readers to be mounted on the opposite sides of the same wall and
aligned along the same geometrical axis, place a metal plate between them and make sure
none of two readers has direct contact with it (allow min. 10 mm space)
For best results mount the proximity readers at least 0.5 m apart
With its relatively weak electromagnetic field generation, reader should not cause any
harmful interference to operation of other equipment. However, its card reading
performance can be affected by other interference generating devices, esp. radio waves
emitting equipment or CRT computer monitors
If card reading performance of the reader deteriorates (e.g. reduced reading range or
incorrect readings) consider reinstallation in a new location.
Screw terminals and wires
Wire
Color
Label
Function
Green
CLK
DATA 0 line for Wiegand, CLOCK for Magstripe and RACS
Brown
DTA
DATA 1 line for Wiegand, DATA for Magstripe and RACS
Yellow
IN1
Input line; in Wiegand and Magstripe formats this line by default controls LED
OPEN
. In RACS format the line can be used to block card reading and PIN
entering. Line is active when shorted to ground
Pink
IN2
Input line; in Wiegand and Magstripe formats this line by default controls
internal buzzer of the reader. Line is active when shorted to ground
Red
+12V
Supply input plus
Blue
GND
Supply input minus
Grey
TAMP
Tamper switch contacts, normally closed, isolated, 24V/50mA. Contacts became
open when unit is detached from the place of installation or upper part of
enclosure is open
White
Содержание PRT12LT
Страница 9: ...PRTxxLT series readers Operating Manual doc 2019 01 29 9 17...
Страница 10: ...PRTxxLT series readers Operating Manual doc 2019 01 29 10 17...
Страница 11: ...PRTxxLT series readers Operating Manual doc 2019 01 29 11 17...
Страница 12: ...PRTxxLT series readers Operating Manual doc 2019 01 29 12 17...
Страница 13: ...PRTxxLT series readers Operating Manual doc 2019 01 29 13 17...
Страница 14: ...PRTxxLT series readers Operating Manual doc 2019 01 29 14 17...
Страница 15: ...PRTxxLT series readers Operating Manual doc 2019 01 29 15 17...