For Wiegand: 

 

F1=C hex 

 

F2=D hex 

For Magstripe: 

 

F1=FF FF FF FF BC hex (1099511627708 dec) 

 

F2=FF FF FF FF BD hex  (1099511627709 dec) 

2.4.

 

O

PERATING 

M

ODES

 

The PRTxxLT offers following data transmission formats: 

 

Wiegand 26bit 

 

Wiegand 32bit, normal mode (from MSB to LSB) 

 

Wiegand 32bit, reverse order (from LSB to MSB) 

 

Wiegand 34bit 

 

Wiegand 42bit 

 

Wiegand 66bit  

 

Magstripe (ABA Track II emulation, also called Clock & Data) 

 

RACS address ID0..3 (addressable format for communication with Roger controllers) 

Wiegand Formats 

When  using 

Wiegand

  transmission  format,  data  is 

transmitted to the host via CLK and DTA lines. Depending 
on  the  selected  version  of  the  transmission  format,  the 
reader can send 26, 32, 34, 42 or 66 bits to the host. PIN 
can be transmitted as a whole (when # key is pressed ) 
or each digit separately – see section 3.2. 
In 

Wiegand

  format  all  LED  indicators  and  buzzer  of  the 

reader  can  be  controlled  by  IN1  and  IN2  inputs.  Both 
inputs  (IN1  and  IN2)  are  triggered  by  shorting  them  to 
supply  minus.  Input  functions  can  be  configured  within 
Memory  Reset  procedure.  In  addition,  whenever  card  is 
read  or  PIN  is  entered  reader  activates  momentary  LED 
SYSTEM   and buzzer.  
Wiegand transmission is unidirectional and data is sent to 
host device without receipt confirmation. 

Note:  For  card  codes  which  require  more  bits  than  the 

number of bits available in the selected data transmission format, reader omits the most significant 
bits (MSB-s) of the card code. As a result transmission from a reader is not the same as full card 
code. 

Magstripe Formats 

When  using 

Magstripe

  transmission  format,  data  is 

transmitted  to  the  host  via  CLK  and  DTA  lines.  In 

Magstripe

  format  all  LED  indicators  and  buzzer  of  the 

reader  can  be  controlled  by  IN1  and  IN2  inputs.  Both 
inputs  (IN1  and  IN2)  are  triggered  by  shorting  them  to 
supply  minus.  Input  functions  can  be  configured  within 
Memory  Reset  procedure.  In  addition,  whenever  card  is 
read  or  PIN  is  entered  reader  activates  momentary  LED 
SYSTEM   and buzzer. 
Card  code  is  always  transmitted  as  a  whole  number  (no 
digits  are  lost)  while  PIN  can  be  transmitted  as  a  whole 
(when  #  key  is  pressed  )  or  each  digit  separately  –  see 
section 3.2. 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание PRT12LT

Страница 1: ...xLT series EM 125 kHz readers Firmware version n a Document version Rev I This document refers to following products PRT12LT PRT12LT BK PRT32LT PRT42LT PRT42LT BK PRT62LT PRT64LT PRT66LT Operating Man...

Страница 2: ...and or PIN s The PRTxxLT reader works as a slave unit it reads cards PIN s and then transmits collected data to host access controller for further processing 2 1 FEATURES 2 1 1 General EM 125 KHz pro...

Страница 3: ...triggered by shorting them to supply minus Input functions can be configured within Memory Reset procedure In addition whenever card is read or PIN is entered reader activates momentary LED SYSTEM an...

Страница 4: ...des Memory Reset procedure variant 1 for RACS format 1 Power down the unit 2 Remove all connections from CLK and IN1 lines 3 Make electrical bridge between CLK and IN1 4 Restore power 5 While LED OPEN...

Страница 5: ...9 Read card N times where N is equal to programmed digit 0 Read Programming Card 10 times Note Each time you complete the sequence of multiple readings of the programming card wait for the reader to...

Страница 6: ...4 bit number Each key pressed is immediately transmitted to the host controller as a sequence of 4 bits XXXX which represent the code of the pressed key no control bits added This format is compatible...

Страница 7: ...ach key press Key s buffer is cleared if no keys have not been entered within ca 15 seconds Examples Keys entered 123 code transmitted 0123 Keys entered 123456 code transmitted 123456 Table A 8 bit ke...

Страница 8: ...at least 0 5 m apart With its relatively weak electromagnetic field generation reader should not cause any harmful interference to operation of other equipment However its card reading performance ca...

Страница 9: ...PRTxxLT series readers Operating Manual doc 2019 01 29 9 17...

Страница 10: ...PRTxxLT series readers Operating Manual doc 2019 01 29 10 17...

Страница 11: ...PRTxxLT series readers Operating Manual doc 2019 01 29 11 17...

Страница 12: ...PRTxxLT series readers Operating Manual doc 2019 01 29 12 17...

Страница 13: ...PRTxxLT series readers Operating Manual doc 2019 01 29 13 17...

Страница 14: ...PRTxxLT series readers Operating Manual doc 2019 01 29 14 17...

Страница 15: ...PRTxxLT series readers Operating Manual doc 2019 01 29 15 17...

Страница 16: ...Hz EM4100 4102 compatible Communication distance Between access controller and PRT reader max 150 m IP Code PRT12LT PRT12LT BK IP65 PRT32LT IP41 PRT42LT PRT42LT BK IP41 PRT62LT IP65 PRT64LT IP65 PRT66...

Страница 17: ...utdoor proximity reader without keypad dark gray ABS enclosure screw terminals Product History Hardware Firmware Date Description V1 0 fv1 20 29 10 09 Initial product version v1 0 fv1 38 28 07 11 Conf...

Отзывы: