PRTxxLT series readers Operating Manual.doc
2019-01-29
5/17
[30]: LED SYSTEM control.
9.
Enter two digits to define the function of IN2 input in the same way as in case of IN1.
10.
Once the previous step is completed reader automatically ends the
Memory Reset
and
switches to normal operation.
Note: If in the step 6 no function is selected within 9 s or both steps are skipped with # key then
Memory Reset is completed with default settings i.e. IN1=[29] and IN2=[28]. It is forbidden to
assign the same functions to both inputs except for the function [11].
3.2.
P
ROGRAMMING OF
R
EADERS WITHOUT
K
EYPAD
Although some PRTxxLT readers are not equipped with keypad they can still be programmed
manually with the same programming procedures as readers with keypad. The difference in
programming is such that instead of pressing certain keys (like you normally do when
programming readers with keypad) you must emulate key pressing by multiple readings of
Programming Card
(i.e. any EM125kHz card). For example in order to emulate key [9] you must
read
Programming Card
9-times (simply present it to the reader and take it back 9 times) and
then wait approx. 3 seconds for the reader to generate a confirmation signal (two beeps) which
means that series of card readings is accepted as an equivalent of key pressing and the reader is
now waiting for the next step of the programming procedure.
Key
Emulation Method
[1]..[9]
Read card [N]-times where [N] is equal to programmed digit
[0]
Read
Programming Card
10-times
Note: Each time you complete the sequence of multiple readings of the programming card
wait for the reader to generate signal (two beeps) which will confirm that reader has
accepted series of card readings as the equivalent of key pressing.
Example: In order to program [001] operating mode:
1.
[0]: Read 10-times programming card and then wait for two beeps
2.
[0]: Read 10-times programming card and then wait for two beeps
3.
[1]: Read 1-time programming card and then wait for two beeps
3.2.1.
Reader Operating Modes
The factory new reader is pre-configured with
RACS address ID=0
but it can be changed using
Memory Reset procedure. There are following operating modes available for the PRTxxLT series
reader:
Code
Operating mode
Description
000
RACS address ID=0
Reader operates as a slave unit connected to the host
controller that requires RACS data transmission format.
001
RACS address ID=1
002
RACS address ID=2
003
RACS address ID=3
020
Magstripe (only card)
Reader operates as a slave unit connected to the host
controller which requires Magstripe data transmission
format, keys are not transmitted.
021
Magstripe UNITEK (card or PIN)
Reader operates as a slave unit connected to a host
controller which requires Magstripe data transmission,
keys transmitted as single digits, format is compatible with
specification of UNITEK controllers (with transmission of
PIN-s).
10x
26 bit Wiegand
Reader operates as a slave unit connected to the host
controller
that
requires
relevant
Wiegand
data
11x
34 bit Wiegand
Содержание PRT12LT
Страница 9: ...PRTxxLT series readers Operating Manual doc 2019 01 29 9 17...
Страница 10: ...PRTxxLT series readers Operating Manual doc 2019 01 29 10 17...
Страница 11: ...PRTxxLT series readers Operating Manual doc 2019 01 29 11 17...
Страница 12: ...PRTxxLT series readers Operating Manual doc 2019 01 29 12 17...
Страница 13: ...PRTxxLT series readers Operating Manual doc 2019 01 29 13 17...
Страница 14: ...PRTxxLT series readers Operating Manual doc 2019 01 29 14 17...
Страница 15: ...PRTxxLT series readers Operating Manual doc 2019 01 29 15 17...