Roger PRT12LT Скачать руководство пользователя страница 4

PRTxxLT series readers Operating Manual.doc   

 

 

 

 

2019-01-29 

 

4/17 

 

RACS Format 

When  using 

RACS

  format,  the  PRTxxLT  reader 

communicates  with  the  access  controller  via  CLK/DTA 
lines.  Unlike  in  the  Wiegand

 

and

 

Magstripe

 

formats,  the 

PRTxxLT  unit  using 

RACS

  format  requires  an  individual 

address  (ID=0…3)  to  be  set  during  configuration  of 
reader’s  operating  mode  (Memory  Reset  procedure).  In 

RACS 

format,  communications  between  the  PRTxxLT 

reader  and  the  host  is  bidirectional  which  allows  the 
controller  to  monitor  the  communication.  The  reader’s 
LED-s  and  the  buzzer  are  controlled  by  the  host  unit. 
When  all  LED-s  are  flashing  it  indicates  that  reader  lost 
communication with the host unit.  
When  in 

RACS

  mode  triggering  of  the  IN1  disables 

reading  of  the  card  and  keypad.  This  input  can  be  used 
for temporary disabling of the reader. The IN2 is not used 
in 

RACS

 mode. PIN is transmitted as a whole when # key 

is pressed. 

 

3 .

 

P

R O G R A M M I N G

 

3.1.

 

M

EMORY 

R

ESET

 

The 

Memory  Reset

  is  a  procedure  which  erases  reader’s  memory  and  restores  factory  default 

settings. It also enables programming of operating mode and additionally it enables configuration 
of IN1 and IN2 inputs in Wiegand and Magstripe Terminal modes. 

Memory Reset procedure(variant 1 for RACS format): 

1.

 

Power down the unit. 

2.

 

Remove all connections from CLK and IN1 lines. 

3.

 

Make electrical bridge between CLK and IN1. 

4.

 

Restore power. 

5.

 

While  LED  OPEN 

  (green)  is  flashing  and  is  accompanied  with  continuous  sound 

disconnect CLK from IN1.  

6.

 

Wait till LED SYSTEM   starts flashing. 

7.

 

Enter  three  digits  which  will  configure  the  reader  for  required  operating  mode  i.e. 
[000].. [003]. Reader generates two beeps with every entered digit. 

8.

 

Once the previous step is completed reader automatically ends the 

Memory Reset

 and 

switches to normal operation. 

Note: When in step 7 an unknown operating mode is entered or no operating mode is entered for 
20 s then reader will automatically exit the Memory Reset procedure. 

Memory Reset procedure(variant 2 for Wiegand and Magstripe formats): 

1.

 

Power down the unit. 

2.

 

Remove all connections from CLK and IN1 lines. 

3.

 

Make electrical bridge between CLK and IN1. 

4.

 

Restore power. 

5.

 

While  LED  OPEN 

  (green)  is  flashing  and  is  accompanied  with  continuous  sound 

disconnect CLK from IN1.  

6.

 

Wait till LED SYSTEM   starts flashing. 

7.

 

Enter  three  digits  which  will  configure  the  reader  for  required  operating  mode  i.e. 
[020], [021] or [1xx]. Reader generates two beeps with every entered digit. 

8.

 

When LED SYSTEM   is on, enter two digits to define the function of IN1 input: 

[11]: Line off 
[25]: LED STATUS   control 
[28]: Buzzer control 
[29]: LED OPEN   control 

Содержание PRT12LT

Страница 1: ...xLT series EM 125 kHz readers Firmware version n a Document version Rev I This document refers to following products PRT12LT PRT12LT BK PRT32LT PRT42LT PRT42LT BK PRT62LT PRT64LT PRT66LT Operating Man...

Страница 2: ...and or PIN s The PRTxxLT reader works as a slave unit it reads cards PIN s and then transmits collected data to host access controller for further processing 2 1 FEATURES 2 1 1 General EM 125 KHz pro...

Страница 3: ...triggered by shorting them to supply minus Input functions can be configured within Memory Reset procedure In addition whenever card is read or PIN is entered reader activates momentary LED SYSTEM an...

Страница 4: ...des Memory Reset procedure variant 1 for RACS format 1 Power down the unit 2 Remove all connections from CLK and IN1 lines 3 Make electrical bridge between CLK and IN1 4 Restore power 5 While LED OPEN...

Страница 5: ...9 Read card N times where N is equal to programmed digit 0 Read Programming Card 10 times Note Each time you complete the sequence of multiple readings of the programming card wait for the reader to...

Страница 6: ...4 bit number Each key pressed is immediately transmitted to the host controller as a sequence of 4 bits XXXX which represent the code of the pressed key no control bits added This format is compatible...

Страница 7: ...ach key press Key s buffer is cleared if no keys have not been entered within ca 15 seconds Examples Keys entered 123 code transmitted 0123 Keys entered 123456 code transmitted 123456 Table A 8 bit ke...

Страница 8: ...at least 0 5 m apart With its relatively weak electromagnetic field generation reader should not cause any harmful interference to operation of other equipment However its card reading performance ca...

Страница 9: ...PRTxxLT series readers Operating Manual doc 2019 01 29 9 17...

Страница 10: ...PRTxxLT series readers Operating Manual doc 2019 01 29 10 17...

Страница 11: ...PRTxxLT series readers Operating Manual doc 2019 01 29 11 17...

Страница 12: ...PRTxxLT series readers Operating Manual doc 2019 01 29 12 17...

Страница 13: ...PRTxxLT series readers Operating Manual doc 2019 01 29 13 17...

Страница 14: ...PRTxxLT series readers Operating Manual doc 2019 01 29 14 17...

Страница 15: ...PRTxxLT series readers Operating Manual doc 2019 01 29 15 17...

Страница 16: ...Hz EM4100 4102 compatible Communication distance Between access controller and PRT reader max 150 m IP Code PRT12LT PRT12LT BK IP65 PRT32LT IP41 PRT42LT PRT42LT BK IP41 PRT62LT IP65 PRT64LT IP65 PRT66...

Страница 17: ...utdoor proximity reader without keypad dark gray ABS enclosure screw terminals Product History Hardware Firmware Date Description V1 0 fv1 20 29 10 09 Initial product version v1 0 fv1 38 28 07 11 Conf...

Отзывы: