[83][S][KL] – Programming “Pulse on Arming” timer, S=0..1, KL=01..99, default: S=0
KL=02
This timer defines duration time for pulse generated on [52] output. Program S=0 for seconds or
S=1 for minutes.
[84][S][KL] – Programming “Pulse on Disarming” timer, S=0..1, KL=01..99, default: S=0
KL=02
This timer defines duration time for pulse generated on [53] output. Program S=0 for seconds or
S=1 for minutes.
[85][S][KL] – Programming “Pulse on Arming/Disarming” timer, S=0..1, KL=01..99,
default: S=0 KL=02
This timer defines duration time for pulse generated on [54] output. Program S=0 for seconds or
S=1 for minutes.
[#] - Exit from Installer Programming mode
Reader leaves
Installer Programming
mode and returns to normal operation (either Armed or
Disarmed) depending on the state it was before.
Note: If you don’t press any key within 3 min. reader will automatically leave the
Installer
Programming
mode.
8.1.
I
NPUT
/O
UTPUT
F
UNCTIONS
Input/Output Functions
Code
Name
Description
11
Line Off
Line is disabled and reader ignores electrical states on this
line.
21
Door Contact
Input, when shorted with supply minus indicates that
controlled door is closed.
22
Exit Button
Input, shorting this line with supply minus triggers
[41]:
Door Lock
and
[42]: Exit Door Lock
outputs (when
programmed) for time specified by
Door Unlock Time.
This
input doesn’t activate
[43]: Entry Door Lock
.
23
Arming Disabled
Input, as long as line is shorted with supply minus reader
disables TOGGLE and TOGGLE LTD user from switching the
reader into
Armed
mode.
24
Arming/Disarming
Key Switch
Input, when line is shorted to supply minus reader switches
unconditionally to
Disarmed
mode, when line is open reader
returns and stay in
Armed
mode.
25
LED STATUS
Input, when programmed it controls LED STATUS and this
LED no longer presents current arming mode of the reader.
When line is shorted to supply minus LED STATUS lights in
green, when open lights in red.
26
Tamper
Input, normally closed, opening this input (no matter in
Armed
mode or in
Disarmed
mode) will start
Tamper
Alarm
and
General Alarm
.
27
Intruder
Input, normally closed to supply minus, opening this input
during
Armed
mode will start
Intruder Alarm
and
General
Alarm.
28
Buzzer Control
Input, when shorted with supply minus activates buzzer.
Содержание PRT12EM
Страница 43: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 43 from 59...
Страница 50: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 50 from 59...
Страница 51: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 51 from 59...
Страница 52: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 52 from 59...
Страница 53: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 53 from 59...
Страница 54: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 54 from 59...
Страница 55: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 55 from 59...
Страница 56: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 56 from 59...
Страница 57: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 57 from 59...
Страница 58: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 58 from 59...