PRT-EM Series Readers fv 1.29 and 2.29 Rev. J.doc
2012-01-05
Page 16 from 59
When LED SYSTEM is blinking, once again enroll your TOGGLE user PIN code
Reader will change its arming state and LED STATUS will change its color
Example 3: Rearming the reader by TOGGLE user when Card and PIN option is active
Present your TOGGLE user card, LED OPEN starts blinking which means that reader
waits for TOGGLE PIN
Enroll your TOGGLE user PIN
Once accepted, reader will grant you access (assuming that access is not disabled by option
Access disabled when reader armed
) and LED SYSTEM starts blinking
When LED SYSTEM is blinking, once again present your TOGGLE card or enter you
TOGGLE PIN
Reader will change arming mode and LED STATUS will change its color
Arming/disarming by input
With input programmed to option
[24]: Arming/Disarming Key Switch
the current arming
mode of the reader is solely controlled by the electrical state on this input. When line is open (not
triggered) reader is forced to
Armed
mode, when closed (triggered) reader switches to
Disarmed
mode and remains in this state as long as line is active.
When reader’s arming mode is controlled through input
[24]
the usage of TOGGLE and TOGGLE
LTD card/PIN is modified. In this case using TOGGLE/TOGGLE LTD card/PIN changes temporary
(for approx. 8 sec.) current reader’s arming mode. If during this period the signal connected to
input
[24]
will change its state (what would mean that controlled alarm system changed its arming
mode as well) then the reader will remain in this new arming mode. In opposite, when during this
limited 8 sec. period the input
[24]
will not change its state (what would mean that the alarm
system did not changed its arming mode) reader will restore previous arming mode.
Note: When reader’s arming mode is controlled through input
[24]
the condition of the input
[23]:
Arming Disabled
(if programmed) is limited to disable the use of TOGGLE/TOGLLE LTD user
card/PIN and doesn’t affect process of arming and disarming.
Using reader for arming/disarming of the alarm system
There are several scenarios which can be used for integration between alarm system and the
reader. Below, you will find the most complex way for integration between alarm system and the
reader.
Содержание PRT12EM
Страница 43: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 43 from 59...
Страница 50: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 50 from 59...
Страница 51: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 51 from 59...
Страница 52: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 52 from 59...
Страница 53: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 53 from 59...
Страница 54: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 54 from 59...
Страница 55: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 55 from 59...
Страница 56: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 56 from 59...
Страница 57: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 57 from 59...
Страница 58: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 58 from 59...