Roger PR611 Скачать руководство пользователя страница 8

PR611 and PR621 Installation guide Rev.B EN 

2009-11-06 

 

 
Page 

8

 of 

13

 

 

Connections 
Name Terminal 

number 

(for 
products 

equipped 
with screw 

terminals) 

Wire Color  

(for versions 

equipped with pig 
tail cable) 

Purpose 

+12V 

Red 

Positive power supply contact, 10–15V DC 

GND 

Black 

Negative power supply contact and reference 

potential for RS485 communication bus, inputs 
and CLK/DTA interface 

IN1 

Pink 

IN1 input line, internally connected to the power 
supply plus (+12V) through a 5.6k

 resistor  

IN2 

Blue 

IN2 input line, internally connected to the power 

supply plus through a 5.6k

 resistor  

IN3 

White-yellow 

IN3 input line, internally connected to the power 

supply plus through a 5.6k

 resistor  

RS485-B 

Green-white 

RS485 communication bus, B line 

RS485-A 

Brown 

RS485 communication bus, A line 

CLK 

White 

RACS Clock & Data communication interface, 

CLOCK line 

DTA 

Green 

RACS Clock & Data communication interface, 

DATA line 

TMP-A 10  Yellow 

Anti-sabotage 

contact, line A, rated 24V/50mA 

TMP-B 11  Grey 

Anti-sabotage 

contact, line B, rated 24V/50mA 

IO2 

12 

Green-brown 

IO2 transistor output of open collector type, rated 

15V DC/1.0A 

IO1 

13 

Yellow-brown 

IO1 transistor output of open collector type, rated 

15V DC/1.0A 

REL1-NC 

14 

Grey-pink 

REL1 relay output, contact normally closed rated 
24V/1.5A 

REL1-COM 15 

Red-blue 

REL1 

relay output, common contact, rated 

24V/1.5A 

REL1-NO 16 

Violet 

REL1 

relay 

output, contact normally open rated 

24V/1.5A 

 

Содержание PR611

Страница 1: ...Installation Guide for PR611 and PR621 v1 0 Access Controllers Rev B ...

Страница 2: ...the separate wire The other solution is to individually ground connect to earth each of GND terminals However the latter solution is not recommended because when grounding potentials in different locations of installation are not the same the equalizing current will flow through the system s power supply lines That in turn can cause disruption of system work or even its damage Readers can be insta...

Страница 3: ... limit negative impact of overvoltages it is necessary to utilize a semiconductor diode of general use e g 1N4007 one piece of such diode is delivered with the controller It should be connected as close as possible to the inductive element electric strike or magnetic lock The door lock device element can be supplied from the same power source as the controller but for such purpose the separate pai...

Страница 4: ...communication through a computer network LAN or WAN Connecting Readers and Extension Modules The controller can cooperate with one additional reader of PRT series configured to RACS mode with ID0 address It can also cooperate with XM 2 I O extension module Both an additional reader and an extension module can be connected to the controller using the same CLK and DTA lines For CLK and DTA lines any...

Страница 5: ...mming a MASTER card and PIN as well as setting up a new address ID number Remove all connections from CLK and DTA lines Short CLK and DTA lines Restart device switch power supply off and then on or short RST contacts for a while all the LED indicators on the reader will be lit Remove the bridge between CLK and DTA lines the LEDs on the reader will be off and the LED OPEN green will start flashing ...

Страница 6: ...is the software used for upgrading firmware it can be downloaded at www roger pl After the firmware is upgraded always perform the Memory Reset procedure and assign a proper ID address to the controller If the controller being upgraded worked in the RACS system before you need to assign to it appropriate ID address after the upgrade the same which it was assigned before the upgrade Then you need t...

Страница 7: ...on metallic spacer 10 mm thick at a minimum It is recommended that the reader be installed at a distance not lower than 0 5 m from the other reader All the devices communicating between themselves readers extension modules controllers should have be connected to the same common minus potential Optionally system supply minus can be earthed in one arbitrary selected location Do not connect system su...

Страница 8: ...t line internally connected to the power supply plus through a 5 6kΩ resistor RS485 B 6 Green white RS485 communication bus B line RS485 A 7 Brown RS485 communication bus A line CLK 8 White RACS Clock Data communication interface CLOCK line DTA 9 Green RACS Clock Data communication interface DATA line TMP A 10 Yellow Anti sabotage contact line A rated 24V 50mA TMP B 11 Grey Anti sabotage contact l...

Страница 9: ...cards depends on card type and quality Proximity cards EM 125 KHz EM4100 4102 compatible Distances RS485 comm bus up to 1200m Between an additional reader and the controller max 150 m Between a reader and XM 2 XM 8 expansion modules max 150 m Environmental class according to EN 50131 1 Class IV outdoor general conditions temperature 25 C 60 C relative humidity 10 to 95 Dimensions PR611 115 X 80 X ...

Страница 10: ...The module can be located in a distance of 150 m from the host device controller XM 2 PCB XM 2 PCB module without enclosure UT 2 RS232 RS485 communication interface UT 2USB USB RS485 communication interface RUD 1 USB RS485 communication interface with 12V DC 150mA supply output UT 4 Ethernet RS485 RS232 communication interface Contact Roger sp j 82 416 Gościszewo Gościszewo 59 Tel 48 55 272 01 32 ...

Страница 11: ...PR611 and PR621 Installation guide Rev B EN 2009 11 06 Page 11 of 13 ...

Страница 12: ...PR611 and PR621 Installation guide Rev B EN 2009 11 06 Page 12 of 13 ...

Страница 13: ...PR611 and PR621 Installation guide Rev B EN 2009 11 06 Page 13 of 13 ...