Inputs 

Eight (IN1-

IN8) NO/NC inputs, electrically biased to +12V via 15kΩ resistor, 

triggering level app. 3.5V 

Relay outputs 

Two (REL1,REL2) relay outputs with single NO/NC contact, 30V/1.5A (REL1) and 
230VAC/5A (REL2) rated 

Transistor outputs 

Two (IO1,IO2) open collector outputs, 15VDC/1A rated 

Power supply outputs 

Two power supply outputs: 12VDC/0.2A (TML) and 12VDC/1A (AUX) rated 

Distances 

Between controller and expander (RS485): max. 1200m 

Between expander and Wiegand reader: max. 100 m 

Between expander and PRT reader (RACS CLK/DTA): max. 150 m 

Environmental class  

Class I, indoor general conditions, temperature: +5°C to +40°C, relative humidity: 
10 to 95% (no condensation) 

Dimensions 

80 x 115 x 28mm  

Weight 

approx. 100g 

Certificates 

CE 

 

Ordering information 

Product 

Description 

MCX402DR-BRD 

I/O expander for door control with Wiegand or PRT readers 

MCX402-1-KIT 

1-door expander kit 

MCX402-2-KIT 

2-door expander kit 

Product history 

Version 

Date 

Description 

MCX402DR v1.0 

10/2017 

The first commercial version of the product 

 

 

This symbol placed on a product or packaging indicates that the product 
should not be disposed of with other wastes as this may have a negative 
impact on the environment and health. The user is obliged to deliver 
equipment to the designated collection points of electric and electronic 
waste. For detailed information on recycling, contact your local authorities, 
waste disposal company or point of purchase. Separate collection and 
recycling of this type of waste contributes to the protection of the natural 
resources and is safe to health and the environment. Weight of the 
equipment is specified in the document. 

 

Contact: 

Roger sp. z o.o. sp.k. 

82-400 Sztum 

Go

ściszewo 59 

Tel.: +48 55 272 0132 
Fax: +48 55 272 0133 

Tech. support: +48 55 267 0126 

E-mail: 

[email protected]

 

Web: 

www.roger.pl

 

Содержание MCX402DR-BRD

Страница 1: ...Roger Access Control System MCX402DR BRD I O expander Operating Manual Product version 1 0 Firmware version 1 0 2 255 Document version Rev B...

Страница 2: ...ery The expander is offered individually as electronic module or as a component of MCX402 1 KIT for read in out door control or as a component of MCX402 2 KIT for two read in doors control In case of...

Страница 3: ...from 230VAC 18VAC 40VA transformer and then it offers 13 8VDC power outputs AUX TML for external devices Optionally the expander can be supplied from 12VDC or 24VDC but in case of 12VDC the backup ba...

Страница 4: ...mal state and is shorted to ground when triggered Output with reversed polarity operates with inverted logic It is shorted to ground in normal state and represents high impedance when triggered The co...

Страница 5: ...ad in read out door with PRT readers A and Wiegand readers B Connection of expander to controller The expander is not operated as standalone device but as an extension of MC16 access controller It is...

Страница 6: ...erVDM software address The factory new expander has ID 100 software address Addressing with jumpers Every time the address is modified the expander must be restarted with RST button or switching power...

Страница 7: ...its every pressed key separately Range Yes No Default value Yes Min PIN length Parameter defines minimal number of digits in PIN Range 0 8 When set to 0 then PIN is disabled Default value 4 Max PIN le...

Страница 8: ...ment Parameter defines any text or comment which corresponds to the object It is later displayed in VISO program CDI comment as above Card code length Parameter defines type of Wiegand 26 66bit interf...

Страница 9: ...RT readers then another firmware must be uploaded Such firmware is available at www roger pl Firmware update is also used in case of migration from RACS 4 to RACS 5 when PR411 and PR402 controllers ar...

Страница 10: ...ne CLK GND Ground DTA RACS CLK DTA interface line DTA IN3 IN3 input line GND Ground IN4 IN4 input line A RS485 communication bus line A TML Power supply output 12VDC 0 2A B RS485 communication bus lin...

Страница 11: ...RD I O expander for door control with Wiegand or PRT readers MCX402 1 KIT 1 door expander kit MCX402 2 KIT 2 door expander kit Product history Version Date Description MCX402DR v1 0 10 2017 The first...

Отзывы: