MCX402DR Operating Manual.doc
2018-09-03
11/11
Inputs
Eight (IN1-
IN8) NO/NC inputs, electrically biased to +12V via 15kΩ resistor,
triggering level app. 3.5V
Relay outputs
Two (REL1,REL2) relay outputs with single NO/NC contact, 30V/1.5A (REL1) and
230VAC/5A (REL2) rated
Transistor outputs
Two (IO1,IO2) open collector outputs, 15VDC/1A rated
Power supply outputs
Two power supply outputs: 12VDC/0.2A (TML) and 12VDC/1A (AUX) rated
Distances
Between controller and expander (RS485): max. 1200m
Between expander and Wiegand reader: max. 100 m
Between expander and PRT reader (RACS CLK/DTA): max. 150 m
Environmental class
Class I, indoor general conditions, temperature: +5°C to +40°C, relative humidity:
10 to 95% (no condensation)
Dimensions
80 x 115 x 28mm
Weight
approx. 100g
Certificates
CE
Ordering information
Product
Description
MCX402DR-BRD
I/O expander for door control with Wiegand or PRT readers
MCX402-1-KIT
1-door expander kit
MCX402-2-KIT
2-door expander kit
Product history
Version
Date
Description
MCX402DR v1.0
10/2017
The first commercial version of the product
This symbol placed on a product or packaging indicates that the product
should not be disposed of with other wastes as this may have a negative
impact on the environment and health. The user is obliged to deliver
equipment to the designated collection points of electric and electronic
waste. For detailed information on recycling, contact your local authorities,
waste disposal company or point of purchase. Separate collection and
recycling of this type of waste contributes to the protection of the natural
resources and is safe to health and the environment. Weight of the
equipment is specified in the document.
Contact:
Roger sp. z o.o. sp.k.
82-400 Sztum
Go
ściszewo 59
Tel.: +48 55 272 0132
Fax: +48 55 272 0133
Tech. support: +48 55 267 0126
E-mail:
Web:
www.roger.pl