MCT64E MCT66E Operating Manual 

  

09.07.2020 

 

9/15 

 

Installation guidelines 

  The  terminal  should  be  mounted  on  a  vertical  structure  (wall)  away  from  sources  of  heat  and 

moisture. 

  Front  panel  should  be  attached  in  such  way  as  the  tamper  detector  (fig.  4)  would  firmly  press  the 

back panel. 

  All electrical connections should be done with disconnected power supply. 

  If  the  terminal  and  controller  are  not  supplied  from  the  same  PSU  then  GND  terminals  of  both 

devices must be connected with any wire. 

  Clean  front  panel  regularly  by  means  of  wet  cloth  and  mild  detergent.  Do  not  clean  by  means  of 

abrasive materials and strong cleaners like alcohols, solvents, etc. Damages to screen surface are 
beyond the scope of warranty. 

3.

 

O

PERATION SCENARIOS

 

The terminal  when connected to MC16  access  controller can  be  at the same time used  for access control 
and Time&Attendance. The example of connection diagram for such scenario is shown in fig. 7 where inputs 
and outputs from MC16 board are used and in fig. 8 where inputs and outputs from terminal are used. The 
terminal  can  also  operate  with MC16 controller  using  MCX2D/MCX4D  expanders  as  in  case  of  M16-PAC-
KIT series. Various scenarios of operation with MC16 controllers are presented in AN002 application note. 
 

 

Fig. 7 Typical connection diagram for the terminal and MC16 access controller 

Содержание MCT64E-IO

Страница 1: ...Roger Access Control System MCT64E IO and MCT66E IO Operating Manual Product version 1 1 Firmware version 1 0 4 or newer Document version Rev A...

Страница 2: ...f 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or from dedicated power supply unit The supply wire diameter must be selected in such...

Страница 3: ...The matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded tw...

Страница 4: ...uzzer Terminals are equipped with buzzer which is used to signal integral functions and it can be additionally programmed with other available functions within high level configuration VISO Inputs Ter...

Страница 5: ...kHz cards EM125kHz proximity cards are widely used in office buildings If it is necessary to ensure higher level of security then MIFARE card readers e g MCT12M are recommended The technical character...

Страница 6: ...RS485 bus line B CLK CLK line DTA DTA line TMP Tamper contact TMP Tamper contact IO1 IO1 output line IO2 IO2 output line REL1 NC REL1 relay normally closed contact REL1 COM REL1 relay common contact R...

Страница 7: ...MCT64E MCT66E Operating Manual 09 07 2020 7 15 Fig 5 MCT64E IO installation...

Страница 8: ...MCT64E MCT66E Operating Manual 09 07 2020 8 15 Fig 6 MCT66E IO installation...

Страница 9: ...not clean by means of abrasive materials and strong cleaners like alcohols solvents etc Damages to screen surface are beyond the scope of warranty 3 OPERATION SCENARIOS The terminal when connected to...

Страница 10: ...CT device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically display Configuration tab 4 Ent...

Страница 11: ...both readers Selected input must be connected to synchronisation output of another reader When set to 0 then synchronisation is disabled Typical numbering is 1 IN1 2 IN2 and 3 IN3 Range 0 3 Default v...

Страница 12: ...led Range 0 100 Default value 100 Input types IN1 IN2 IN3 Parameter defines the type of input line Range 1 NO 2 NC Default value 1 NO Input comments IN1 IN2 IN3 Parameter defines any text or comment w...

Страница 13: ...it Zero digit is emulated with 10 readings Example Programming of ID 101 address with card readings 1 Read card 1 time and wait for two beeps 2 Read card 10 times and wait for two beeps 3 Read card 1...

Страница 14: ...ronmental class according to EN 50133 1 Class IV outdoor general conditions temperature 25 C to 60 C relative humidity 10 to 95 no condensation Dimensions H x W x D MCT64E IO 115 x 80 x 35 mm MCT66E I...

Страница 15: ...electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste c...

Отзывы: