MCT64E MCT66E Operating Manual
09.07.2020
9/15
Installation guidelines
The terminal should be mounted on a vertical structure (wall) away from sources of heat and
moisture.
Front panel should be attached in such way as the tamper detector (fig. 4) would firmly press the
back panel.
All electrical connections should be done with disconnected power supply.
If the terminal and controller are not supplied from the same PSU then GND terminals of both
devices must be connected with any wire.
Clean front panel regularly by means of wet cloth and mild detergent. Do not clean by means of
abrasive materials and strong cleaners like alcohols, solvents, etc. Damages to screen surface are
beyond the scope of warranty.
3.
O
PERATION SCENARIOS
The terminal when connected to MC16 access controller can be at the same time used for access control
and Time&Attendance. The example of connection diagram for such scenario is shown in fig. 7 where inputs
and outputs from MC16 board are used and in fig. 8 where inputs and outputs from terminal are used. The
terminal can also operate with MC16 controller using MCX2D/MCX4D expanders as in case of M16-PAC-
KIT series. Various scenarios of operation with MC16 controllers are presented in AN002 application note.
Fig. 7 Typical connection diagram for the terminal and MC16 access controller