MCT64E MCT66E Operating Manual 

  

09.07.2020 

 

4/15 

 

Keypad 

MCT64E-IO is equipped with numeric keypad and backlight. The keypad can be used for user identification 
with PIN and for various keypad commands. By default, the key [#] is used for PIN confirming. 
Numeric keypad includes [*] and [#] keys which can be configured as function keys. 

LED indicators 

Terminals are equipped with three LED indicators which are used to signal integral functions and they can 
be additionally programmed with other available functions within high level configuration (VISO). 

Table 2. LED indicators 

Indicator 

Symbol  Colour 

Integral functions 

LED 
STATUS  

 

Red / green 

Default colour of the indicator is red. If the terminal is assigned to 
Alarm  Zone  then  the  LED  indicates  zone  arming  (red)  or 
disarming (green).  

LED OPEN  

 

Green 

LED indicates access granting. 

LED 
SYSTEM  

 

Orange 

LED indicates card reading and can signal other system functions 
including device malfunction. 

 

Note: Synchronic pulsing of LED indicators signifies lost communication with MC16 controller.  

Buzzer 

Terminals  are  equipped  with  buzzer  which  is  used  to  signal  integral  functions  and  it  can  be  additionally 
programmed with other available functions within high level configuration (VISO). 

Inputs 

Terminals  offer  3  general  purpose  inputs  of  NO/NC  type.  Input  types  are  defined  within  low  level 
configuration  (RogerVDM).  Input  functions  are  assigned  within  high  level  configuration  (VISO).  Multiple 
functions can be assigned to the same input at the same time. 

Tamper detector 

Built-

in tamper (sabotage) detector enables detection of unauthorized opening of device’s enclosure as well 

as  detachment  of  the  enclosure  from  wall.  The  detector  is  internally  connected  to  TMP  screw  terminals.  It 
does not require low level configuration (RogerVDM) but it is necessary to connect it to controller with wires 
as in example in fig. 3. It is also essential to mount front panel in such way as  the tamper detector  (fig. 4) 
would firmly press the back panel. 
The  input  of  controller  for  connection  of  tamper  loop  requires  low  level  configuration  in  regard  of  NC  type 
(RogerVDM) and high level configuration consisting in assignment of the  function 

[133] Tamper Toggle o

the level of a 

Main Board

 of a controller in VISO software navigation tree. 

Содержание MCT64E-IO

Страница 1: ...Roger Access Control System MCT64E IO and MCT66E IO Operating Manual Product version 1 1 Firmware version 1 0 4 or newer Document version Rev A...

Страница 2: ...f 11 15VDC It can be supplied from MCX2D MCX4D expander of MC16 PAC KIT from MC16 access controller e g TML output or from dedicated power supply unit The supply wire diameter must be selected in such...

Страница 3: ...The matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded tw...

Страница 4: ...uzzer Terminals are equipped with buzzer which is used to signal integral functions and it can be additionally programmed with other available functions within high level configuration VISO Inputs Ter...

Страница 5: ...kHz cards EM125kHz proximity cards are widely used in office buildings If it is necessary to ensure higher level of security then MIFARE card readers e g MCT12M are recommended The technical character...

Страница 6: ...RS485 bus line B CLK CLK line DTA DTA line TMP Tamper contact TMP Tamper contact IO1 IO1 output line IO2 IO2 output line REL1 NC REL1 relay normally closed contact REL1 COM REL1 relay common contact R...

Страница 7: ...MCT64E MCT66E Operating Manual 09 07 2020 7 15 Fig 5 MCT64E IO installation...

Страница 8: ...MCT64E MCT66E Operating Manual 09 07 2020 8 15 Fig 6 MCT66E IO installation...

Страница 9: ...not clean by means of abrasive materials and strong cleaners like alcohols solvents etc Damages to screen surface are beyond the scope of warranty 3 OPERATION SCENARIOS The terminal when connected to...

Страница 10: ...CT device firmware version RS485 communication channel and serial port with RUD 1 interface 3 Click Connect the program will establish connection and will automatically display Configuration tab 4 Ent...

Страница 11: ...both readers Selected input must be connected to synchronisation output of another reader When set to 0 then synchronisation is disabled Typical numbering is 1 IN1 2 IN2 and 3 IN3 Range 0 3 Default v...

Страница 12: ...led Range 0 100 Default value 100 Input types IN1 IN2 IN3 Parameter defines the type of input line Range 1 NO 2 NC Default value 1 NO Input comments IN1 IN2 IN3 Parameter defines any text or comment w...

Страница 13: ...it Zero digit is emulated with 10 readings Example Programming of ID 101 address with card readings 1 Read card 1 time and wait for two beeps 2 Read card 10 times and wait for two beeps 3 Read card 1...

Страница 14: ...ronmental class according to EN 50133 1 Class IV outdoor general conditions temperature 25 C to 60 C relative humidity 10 to 95 no condensation Dimensions H x W x D MCT64E IO 115 x 80 x 35 mm MCT66E I...

Страница 15: ...electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste c...

Отзывы: