HRT82MF Installation Guide Rev.B
2015-08-13
© 2015 ROGER sp.j. All rights reserved.
10/12
Card/PIN Buffer
Timeout
The device periodically resets its Card/PIN buffer when
selected timeout [0,5s] elapses. When 0 is selected then
buffer reset is off.
Card/PIN Frames
Encryption
When activated, frames with data from Card/PIN buffer are
encrypted (EEA).
4.2 Firmware update
HRT82MF firmware can be updated with RogerVDM (available at
www.roger.pl
) after connection to
RUD-1 communication interface.
Firmware update procedure
1.
Connect device to RUD-1 communication interface according to fig. 5
2.
Install and start RogerVDM software
3.
Close
Select Device window
4.
In top menu select
Tools->Update firmware
5.
In the opened window select device, port with connected RUD-1 and specify path to firmware
file (*.hex) – see fig. 8
6.
According to displayed message place jumper on FDM pins and restart the device (place and
remove jumper on RST pins or switch power supply off and on)
7.
Select
Update button
8.
After firmware upload remove jumper from FDM pins and reset device (place and remove
jumper on RST pins or switch power supply off and on)
Fig. 8 Firmware update window in RogerVDM software
4.3 Memory reset
In order to restore HRT82MF factory default settings place jumper on MEM pins and then restart
the device either by placing and removing jumper on RST pins or by switching power supply off and
on. Moreover, memory reset is also part of connection and configuration procedure (see 4.1).