[78]: CPR passive
Output Active when CPR is disabled (switched OFF by
managing program).
[79]: Internal failure
Output Line indicates an internal problem of CPR module
(clock unset, configuration data error, event memory
error); output remains active as long as
corresponding state exists.
[80]: Buffer problem (composite)
Output Line is pulsing when event buffer is occupied in more
than 75%; output is active steady (without
modulation) when buffer is nearly 100% occupied;
output remains active as long as corresponding state
exists.
Info: When buffer is full, the newly coming events
erase the oldest ones.
[81]: Tamper alarm
Output Line indicates tamper alarm; it remains active for
180s or can be cleared earlier from input [01] or
[12].
[82]: Supply alarm
Output Line indicates supply problem (low battery level,
battery failure or lack of AC supply); output remains
active for 180s or can be cleared earlier from input
[01] or [12].
[83]: Communication alarm
Output Line indicates lack of communication with any of
controllers in system; output returns when
communication with all controllers is restored.
[84]: Buffer alarm
Output Line indicates that event buffer in fully occupied;
output remains active as long as mentioned state
exists.
Info: When buffer is full, the newly coming events
erase the oldest ones.
[85]: Buffer prealarm
Output Line indicates event buffer in occupied in more than
75%; output remains active as long as mentioned
state exists.
[86]: Internal failure (momentary)
Output Same as [79] however it returns automatically after
180s or can be cleared earlier from input [01] or
[12].
[87]: Communication alarm
(momentary)
Output Same as [83] however it returns automatically after
180s or can be cleared earlier from input [01] or
[12].
[88]: Buffer alarm (momentary)
Output Same as [84] however it returns automatically after
180s or can be cleared earlier from input [01] or
[12].
[89]: Buffer prealarm (momentary) Output Same as [85] however it returns automatically after
180s or can be cleared earlier from input [01] or
[12].
[90]: Low battery (momentary)
Output Same as [74] however it returns automatically after
180s or can be cleared earlier from input [01] or
[12].
[91]: AC lost (momentary)
Output Same as [75] however it returns automatically after
180s or can be cleared earlier from input [01] or
[12].
[92]: Battery failure (momentary)
Output Same as [76] however it returns automatically after
180s or can be cleared earlier from input [01] or