Fig. 11 Encrypted communication in CPR32-NET
Fig. 12 Encrypted communication in PR Master
4.4.2 Communication with CPR32-NET from dedicated host
It is possible to limit communication with CPR32-NET to dedicated host with particular IP address in
order to increase security of communication. This is can be configured by means of CPR32-NET
webpage in the menu
Networks
, in the field
Dedicated host
, where IP address of such
authorized computer can be entered.
4.5 Full memory reset of CPR32-NET
Full memory reset of CPR32-NET results in erasing of current settings and restoring of default
settings.
Reset procedure
·
Switch off CPR32-NET power supply
·
Remove connections to CLK and DTA terminals (if applicable)
·
Connect CLK terminal with DTA terminal
·
Switch on CPR32-NET power supply, all LEDs shall be on
·
Wait until all LEDs start to flash