Roger BG30 Series Скачать руководство пользователя страница 2

33

 

General safety precautions

Failure to respect the information given in this manual may cause personal injury or damage to the 

device.

This installation manual is intended for qualified personnel only.  

ROGER TECHNOLOGY cannot be held responsible for any damage or injury due to improper use or any use other the intended usage indicated in 

this manual. 

Installation,  electrical  connections  and  adjustments  must  be  performed  by  qualified  personnel,  in  accordance  with  best  practices  and  in 

compliance with applicable regulations.

Read the instructions carefully before installing the product. Bad installation could be dangerous. 

Before installing the product, make sure it is in perfect condition:

 

if in doubt, do not use the equipment and contact qualified personnel only.

Do not install the product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents a serious safety hazard.

Before installing the motorisation device, make all the necessary structural modifications to create safety clearance and to guard or isolate all the 

crushing, shearing, trapping and general hazardous areas.

Make sure the existing structure is up to standard in terms of strength and stability.

ROGER TECHNOLOGY is not responsible for failure to observe Good Working Methods when building the frames to be motorised, or for any 

deformation during use.

The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking into account: applicable laws and directives, Good 

Working Methods, installation premises, system operating logic and the forces developed by the motorised door or gate.

The safety devices must protect against crushing, cutting, trapping and general danger areas of the motorised door or gate.

The European standards EN 12453 and EN 12455 define the minimum safety requirements for the operation of automatic doors and gates. In 

particular, these standards require the use of force limiting and safety devices (sensing ground plates, photocell barriers, operator detection 

function etc.) intended to detect persons or objects in the operating area and prevent collisions in all circumstances.

Where the safety of the installation is based on an impact force limiting system, it is necessary to verify that the characteristics and performance 

of the automation system are compliant with the requisites of applicable standards and legislation.

The installer is required to measure impact forces and programme the control unit with appropriate speed and torque values to ensure that the 

door or gate remains within the limits defined by the standards EN 12453 and EN 12455.

ROGER TECHNOLOGY declines all responsibility if component parts not compatible with safe and correct operation are fitted.

Display the signs required by law to identify hazardous areas.

Each installation must bear a visible indication of the data identifying the motorised door or gate.

An omnipolar disconnection switch with a contact opening distance of at least 3mm must be fitted on the mains supply.

Make sure that upline from the mains power supply there is a residual current circuit breaker that trips at no more than 0.03A and overcurrent 

cutout upstream of the electrical system in accordance with best practices and in compliance with applicable regulations.

When requested, connect the automation to an effective earthing system

   

that complies with current safety standards.

During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the electrical parts.

The electronic parts must be handled using earthed antistatic conductive arms.

Only use original spare parts for repairing or replacing products.

The installer must supply all information concerning the automatic, manual and emergency operation of the motorised door or gate, and must 

provide the user with the operating instructions.

The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as they are a 

potential source of danger.

Dispose of and recycle the packing components in accordance with the standards in force.

These instruction must be kept and forwarded to all possible future user of the system.

Declaration of Conformity

I the undersigned, as acting legal representative of the manufacturer:

Roger Technology - Via Botticelli 8, 31021 Bonisiolo di Mogliano V.to (TV)

hereby DECLARE that the appliance described hereafter:

Description: Sliding gate automation

Model

: serie BG30

Is conformant with the legal requisites of the following directives:

• Directive 

2014/30/UE

 (EMC Directive) and subsequent amendments;

• Directive 

2014/35/UE

 (Low Voltage Directive) and subsequent amendments;

and that all the standards and/or technical requirements indicated as follows have been applied:

EN 61000-6-3

EN 61000-6-2

EN 60335-1

EN 60335-2-103

Last two figures of year in which marking was applied 

 

|

  

16.

Place

: Mogliano V.to             

Date

: 07/07/2016

Signature  

ROGER TECHNOLOGY is the exclusive proprietor holder of all rights regarding this publication.

ROGER TECHNOLOGY reserves the right to implement any modifications without prior notification. Copying, scanning or any alterations to this document are 

prohibited without express prior authorised from by ROGER TECHNOLOGY.

Содержание BG30 Series

Страница 1: ...BG30 Series Sliding gates automations IS141 Rev 03 15 12 2017 INSTRUCTIONS AND RECOMMENDATIONS FOR THE INSTALLER...

Страница 2: ...oor or gate remains within the limits defined by the standards EN 12453 and EN 12455 ROGER TECHNOLOGY declines all responsibility if component parts not compatible with safe and correct operation are...

Страница 3: ...Barrerafotoel ctricainterior Sensorfotoel tricoexterior 4 Lampeggiante Flashing light Blinkleuchte Clignotant Luz intermitente Lampejante 5 Antenna Antenna Antenne Antenne Antena Antena 6 Selettore a...

Страница 4: ...s zu 1000 kg mit Digitale Kontrolle der Serie B70 mit mechanischem Endchalter Motor ducteur lectrom canique HIGH SPEED BRUSHLESS basse tension utiliser super intensif avec encodeur natif bord irr vers...

Страница 5: ...15 14 PESO MASSIMO ANTA MAXIMUM LEAF WEIGHT H CHSTGEWICHT TOR FL GEL POIDS MAXIMAL VANTAIL PESO M XIMO DE LA HOJA PESO M XIMO DA PORTINHOLA kg 1600 2200 1000 1800 1400 LUNGHEZZA MASSIMA ANTA DOOR MAXI...

Страница 6: ...IRES AVANT L INSTALLATION V rifier que la structure du portail est solide et contr ler la stabilit du vantail d raillement et chutes lat rales qui peuvent causer des dom mages des personnes et des cho...

Страница 7: ...ssel 19 anzieht Den Deckel aufsetzen Fig 1 Fig 2 FR D visser les vis du couvercle et le retirer en tirant vers le haut comme indiqu dans la fig 1 V rifier que les six pieds de r glage ne d passent pa...

Страница 8: ...initiv blockieren 1 2 mm Fig 1 Fig 2 FR REMARQUE Les cr maill res avec denture module 4 sont adapt es pour l installation avec le motor ducteur BG30 D bloquer le motor ducteur voir Guide pour l utilis...

Страница 9: ...e fin de course sur la cr maill re en faisant attention au bon sens d insertion Si les fins de course sont de type m canique R DROIT L GAUCHE fig 1 Si les fins de course sont de type magn tique les fl...

Страница 10: ...t used DE Die elektrischen Anschl sse und die Abnahmepr fung der Antriebe BG30 sind in der Abbildung und im Installationshandbuch des installierten B70 1DCHP Steuerger ts dargestellt FR Les raccordeme...

Страница 11: ...ROGER TECHNOLOGY Via S Botticelli 8 31021 Bonisiolo di Mogliano Veneto TV ITALIA P IVA 01612340263 Tel 39 041 5937023 Fax 39 041 5937024 info rogertechnology com www rogertechnology com...

Отзывы: