CONTACT
DESCRIPTION
32(AP) 28(COM)
The command input (N.C.) available for the connection of the sensor of the
ACS/BA/60
detachable
barrier boom coupling system (fig. 8)
When the
ACS/BA/60
detachable boom safety system intervenes, the contact switches from N.C. to N.O.
Enable the contact via parameter
.
33(ORO) 34(COM)
Clock timer contact input (N.O.).
When the clock function is active, the barrier opens and remains open.
At the end of the programmed time set with the external device (clock) the barrier closes.
The function of this command is determined by parameter
.
33(ORO) 34(COM)
The command input (N.C.) available for the connection of the sensor of the
ACS/BA/60
detachable
barrier boom coupling system (fig. 8)
When the
ACS/BA/60
detachable boom safety system intervenes, the contact switches from N.C. to N.O.
Enable the contact via parameter
.
For systems composed of two MASTER and SLAVE opposing barriers, connect the detachable boom
coupling system sensor of the SLAVE barrier
STRICTLY
to the
ORO
input of the SLAVE control unit.
ENC1
7-way connector for connecting to encoder installed on motor (see fig. 12-13).
WARNING!
Always disconnect from electrical power before disconnecting or connecting the encoder cable.
ENC2
6-way connector for connecting to encoder installed on one side of motor (see fig. 12-13).
WARNING!
Always disconnect from electrical power before disconnecting or connecting the encoder cable.
LED LIGHT
Connector for the (OPTIONAL)
B73/EXP
signal device connection and flashing lights installed on the top
cover (see fig. 14-15).
LOCKS
Connectors for connecting lock device microswitch and safety stop microswitch on barrier inspection hatch
(connection not supplied by ROGER TECHNOLOGY) (see fig. 10-11).
Jumper the other connector if only one connector is connected.
RECEIVER CARD
Connector for slot-in radio receiver board.
The controller has two radio remote control functions by default:
–
PR1
- step mode command (modifiable with parameter
).
–
PR2
- close command (modifiable with parameter
).
B71/BCHP
BI/BCHP
BATTERY CHARGER
BI/BAT/KIT
BATTERY KIT
2x12 Vdc 4.5 Ah
(AGM type ONLY)
Connector for slot-in battery charger board.
In the event of a mains power loss, the controller unit is powered by the batteries. When battery power is
used, the message
E$WW
is shown on the display and the flashing light flashes briefly at intervals until
mains power is restored or until the battery voltage drops below the minimum permissible limit. In this
case,
EW/2
(Battery Low) is shown on the display and the controller unit accepts no commands.
If mains power is lost while the boom is moving, the boom stops and then automatically resumes the
interrupted manoeuvre after 2 seconds.
By setting parameter
to a value different than
, the battery management is enabled. With parameter
the battery operation limitation type is enabled when the voltage drops under a certain threshold.
Parameter
is not available for SLAVE automation systems.
WARNING!
the batteries must always be connected to the electronic controller unit in order to charge.
Periodically (at least every 6 months), check that the batteries are in good working order.
For more information, refer to the installation manual for the
B71/BCHP
or
BI/BCHP
battery charger.
Содержание CTRL
Страница 2: ...2 ...
Страница 16: ...16 13 ENC2 ENC1 LOCKS LED LIGHT ST COM 21 22 ENC2 ENC2 6 FILI 6 WIRES ENC1 7 FILI 7 WIRES ENC1 BIONIK4 ...
Страница 19: ...19 AGILIK KB MESSA A TERRA GROUNDING SCHEME 16 ...
Страница 20: ...20 17 MESSA A TERRA GROUNDING SCHEME BIONIK4 BIONIK4HP BIONIK6 BIONIK8 ...
Страница 290: ...290 ...
Страница 291: ...291 ...