Travel acquisition
For the system to function correctly, the gate travel must be acquired by the control.
10.1
Before starting
1. Select the automation system model installed with the parameter
$
.
KEY:
HIGH SPEED Motor
SELECTION
MODEL
MOTOR
TYPE
CONFIGURATIONS
D
AYRON SERIES
NOTE: for gate leaves up to 2.5 m
D
BE20/200
-
NOTE: for gate leaves up to 3 m
MONOS4
-
NOTE: for gate leaves up to 4 m
2. Select the number of motors installed with the parameter
. This parameter is set for two motors by default.
3. Check that the operator present function is
NOT
enabled (
$
).
OPEN
CLOSE
STOP
4. Install mechanical stops in both the open and closed positions.
5. Move the gate into the closed position. The gate leaves must be against the mechanical stops.
6. Press TEST (see TEST mode in chapter 8) and check the command signal and safety device states. If any safety
devices are not installed, jumper the relative contact or disable the device from the relative parameter (
,
,
,
,
and
).