Description of connections
5.1
Typical installation
3
1
2
2
3
3
7
4
4
5
6
8
9
It is the installer's responsibility to verify the adequacy of the cables in relation to the
devices used in the installation and their technical characteristics.
Recommended cable
1
Power supply
,62*\QQ
2
double insulated cable
2
Motor 1
Cable 3x2,5 mm² (max 10
Q
3x4 mm² (max 30 m) *
Motor 2
Cable 3x2,5 mm² (max 10
Q
3x4 mm² (max 30 m)
3
4LSXSGIPPW6IGIMZIV
F4ES/F4S
Cable 5x0,5 mm
2
(max 20 m)
4
4LSXSGIPPW8VERWQMXXIV
F4ES/F4S
Cable 3x0,5 mm
2
(max 20 m)
5
LED Flashing light
FIFTHY/24
Power supply 24Vdc
Cable 2x1 mm
2
(max 10 m)
6
Antenna
Cable 50 Ohm RG58 (max 10 m)
7
Key selector
R85/60
Cable 3x0,5 mm
2
(max 20 m)
Key pad
H85/TTD - H85/TDS
(connecting to
H85/DEC - H85/DEC2
)
Cable 2x0,5 mm
2
(max 30 m)
H85/DEC - H85/DEC2
(connecting to control unit)
Cable 4x0,5 mm
2
(max 20 m)
The number of conductors increases when using more than
one output contact on
H85/DEC - H85/DEC2
8
Gate open indicator
Power supply 24V DC 3W max
Cable 2x0,5 mm
2
(max 10 m)
9
Courtesy light (Potential free contact)
Power supply 230 Vac (100 W max)
Cable 2x1 mm
2
(max 20 m)
SRP]JSVMRWXEPPEXMSRWMR&3<
SUGGESTIONS:
with existing installations, we recommend checking the cross section of the cables and that
the cables themselves are in good condition.