CE notes about voltage fluctuations and flicker continued 

 

Guideline chart:  

The chart provided here is not a substitute for a test.  It is meant only to help determine when further review of 
standard EN61000-3-3 is needed.  The chart does not cover every circumstance.  Please note: if the machine is rated 
at 120 volts, or 60 Hz, this standard does not apply.  
 
To use this chart, determine how many amps the machine uses during its normal operation.  Is the amperage over 16 
amps?  Determine the amperage of the vibratory feeder when the feeder bowl (or hopper) is operating at its 
maximum feed rate with a full load of parts.  Determine how often the vibratory feeder typically turns on and off.  
Compare the amps and on/off cycles to the chart.   
 
For multiple vibratory feeders only add their amperage together if they always start and stop at the same time.  
Actual testing may prove that the number of On/Off cycles shown in the chart can nearly be doubled when the Soft 
Start pot is adjusted for a one second (or longer) soft start. 
 

Amps rms at 230V 

Maximum On/Off cycles permitted 

16 

1       On/Off cycle per 6 minutes 

15 

1       On/Off cycle per 4.5 minutes 

14 

1       On/Off cycle per 3 minutes 

13 

1       On/Off cycle per 3 minutes 

12 

1       On/Off cycle per 3 minutes 

11 

1       On/Off cycle per 3 minutes 

10 

1       On/Off cycle per 1.5 minutes 

1       On/Off cycle per 1 minute 

1       On/Off cycle per 1 minute 

1 1/3 On/Off cycles per 1 minute 

2       On/Off cycles per 1 minute 

6.5    On/Off cycles per 1 minute 

19     On/Off cycles per 1 minute 

65     On/Off cycles per 1 minute 

195   On/Off cycles per 1 minute 

 Unlimited On/Off cycles per 1 minute 

 
This chart is based on Rectangular voltage changes at equal intervals using the Pst=1 chart, fig. 4 of standard 
EN61000-3-3.  Plt = Pst x 0.65 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  © RODIX Inc. 2006  

E:\Eng\CE\CE Flicker 060511.doc

 

Содержание FEEDER CUBE CE-40 Plus Series

Страница 1: ... Communication Systems LLC Figure 1 Warning label installed on the control Warning There is hazardous voltage inside the control Disconnect power before opening the enclosure Only skilled or instructed persons should open the enclosure An electrically instructed person is a person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid...

Страница 2: ... SOFT Start trimpot clockwise for the gentlest start about a 6 sec ramp up to full output Turn the trimpot fully counter clockwise for no soft start 6 REMOTE OFF ON CONTROL A Run Jumper has been installed at the factory as shown on the enclosed wiring diagram Remote OFF ON operation of the FC 40 Plus Series Feeder Cube control can be configured to operate in one of the following ways A A low curre...

Страница 3: ...ing or operating your Rodix Feeder Cube please call the factory or visit our web site Technical help is available to answer your questions and fax any needed information To return a control for IN or OUT of warranty service please ship it prepaid to Rodix Inc ATTN Repair Department If under warranty Rodix will repair or replace your control at no charge If out of warranty we will repair it and you...

Страница 4: ... OUTPUT 10 INTERLOCK TERMINALS CE 90 PLUS SERIES FEEDER BOWL HOPPER INTERLOCK 11 9 6 CE 40 PLUS SERIES TERM STRIP TB 2 3 B 8 7 DC Voltage from PLC or CE 90 Plus C 12 10 9 LOW VOLTAGE INPUT SWITCHING INTERLOCK TERMINALS 8 CE 40 PLUS SERIES TERM STRIP TB 2 5 OFF ON CONTROL 11 10 30 VDC INPUT VOLTAGE 6 7 The common line is not fused in Europe The common line should be fused for North American machine...

Страница 5: ...ons for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drain wire should be tied to the chassis in the Rodix control The drain wire should be kept shorter than 2 Please see the enclosed picture Example of a drain wire termination 2 Never run I O signal wires...

Страница 6: ...sting was performed by Rodix at L F Research 12790 Route 76 Poplar Grove IL 61065 Machine Description Vibratory Feeder Control Makes CE 41 Plus CE 41H Plus CE 43 Plus CE 43H Plus CE 48 CE 48 Plus CE 48H Plus CE 49 Plus CE 49H Plus CE 91 Plus CE 91H Plus CE 91 2 Plus CE 91 2H Plus CE 91 3 Plus CE 91 3H Plus CE 93 Plus CE 93H Plus CE 98 Plus CE 98H Plus CE 98 2 Plus CE 98 2H Plus CE 98 3 Plus CE 98 ...

Страница 7: ...the standard 1 When the standard does apply When a 230V machine is not powered by a step down transformer there should not be a problem meeting this standard if all the vibratory feeders on one machine operate in the 100 Pulse full wave mode and the combined total amperage for the vibratory feeders is 15 Amps or less However it is harder to meet this standard in the 50 Pulse half wave mode The com...

Страница 8: ...p down transformer that is installed in a factory Thus the machine is powered by a higher voltage distribution system that is not directly connected to the 230V public low voltage system Because of this the machine is outside the scope of the standard1 A machine that is connected to 60Hz power is also outside the scope of the standard When the standard does apply The standard is applicable when a ...

Страница 9: ...gether if they always start and stop at the same time Actual testing may prove that the number of On Off cycles shown in the chart can nearly be doubled when the Soft Start pot is adjusted for a one second or longer soft start Amps rms at 230V Maximum On Off cycles permitted 16 1 On Off cycle per 6 minutes 15 1 On Off cycle per 4 5 minutes 14 1 On Off cycle per 3 minutes 13 1 On Off cycle per 3 mi...

Отзывы: