8. LINE VOLTAGE COMPENSATION
Fluctuations in the line voltage can cause a feeder
bowl to vary its feed rate. The line voltage
compensation feature adjusts the control's output
to help compensate for fluctuations in the supply
voltage. If it becomes necessary to disable this
feature, set “Disable LVC” from the S1
programming chart.
9. SUPPLEMENTARY FEATURES
Special supplementary software features can be
enabled on the 24-210/24-211 circuit boards The
features include: l
inear pot taper
,
0-20mA control
,
e
mpty bowl timer
,
low pulse rates,
and
two speed
pots
. See the S1 Switch Programming Chart. For
more feature information download (or request
from RODIX) the FC-40
Plus
Advanced
Application Note 24-210/24-211.
10. STATUS LEDs
When any of the inputs are active, the associated
LED will turn ON. When the RUN input conditions
are met, the RUN LED will turn ON. See section 6
and the wiring diagram’s ON/OFF Control Guide
for more information on how to satisfy the RUN
conditions.
WARNING:
Fuses should be replaced with a Bussman
ABC or Littelfuse 3AB "Fast Acting" type or
equivalent of manufacturer's original value.
Mounting this control on a vibrating surface
will void the warranty.
WARRANTY
Rodix Control Products are Warranted to be
free from defects in material and workmanship
under normal use for a period of two years
from date of shipment.
For the full description of
the warranty, terms, and software license, please
contact the factory.
For assistance installing or operating your Rodix
Feeder Cube® please call the factory or visit our
web site. Technical help is available to answer
your questions and fax any needed information.
To return a control for IN or OUT of warranty
service, please ship it prepaid to:
Rodix Inc., ATTN: Repair Department
If under warranty, Rodix will repair or replace your
control at no charge; If out of warranty, we will
repair it and you will be billed for the repair
charges (Time and Material) plus the return freight.
Quotes for repairs are available upon request. A
brief note describing the symptoms helps our
technicians address the issue.
Feeder Cube® is a registered TM of Rodix Inc.
Banner
is a registered Trademark of Banner
Engineering Corp
,
TROUBLESHOOTING
For the control to run: The
MAIN CONTROL DIAL
must be turned up or have over 4mA at the 4-
20mA input. Either the DIRECT LED must be lit or
both the INTERLOCK and EXT VOLTS LEDs must
be on. To light the DIRECT LED, connect a Run
Jumper at TB2-6 & TB2-7.
To light the
INTERLOCK LED, a Run Jumper must connect
TB2-5 to TB2-6. To illuminate the EXT VOLTS
LED, TB2-11 & 12 needs a 10-30 VDC signal.
See the “FC-40 Plus Troubleshooting Guide” for
more information. If the feeder only hums, flip the
60/120 dip switch.
DIMENSIONS
RODIX, INC.
2316 23
rd
Ave, Rockford, IL 61104
Toll Free (800) 562-1868, FAX (815) 316-4701
E-mail [email protected]
www.rodix.com
CE-41 Plus 24-211 10/16/2012 Page 3
S1 Programming Chart
Program Description
S1 Switch Positions
SW3
SW4
SW5
Standard
Program
0 0 0
Linear Pot Taper
1
0
0
0-20mA
option
0 1 0
Empty Bowl Timer
1
1
0
Disable
LVC
0 0 1
2-Speed
Operation
1 0 1
30/40 Pulse Operation
0
1
1
Low Amplitude at “1”
1
1
1