8. LINE VOLTAGE COMPENSATION 

Fluctuations in the line voltage can cause a feeder 
bowl to vary its feed rate.  The line voltage 
compensation feature adjusts the control's output 
to help compensate for fluctuations in the supply 
voltage. If it becomes necessary to disable this 
feature, set “Disable LVC” from the S1 
programming chart. 

 

9. SUPPLEMENTARY FEATURES 

Special supplementary software features can be 
enabled on the 24-210/24-211 circuit boards The 
features include: l

inear pot taper

0-20mA control

e

mpty bowl timer

low pulse rates, 

and

 two speed 

pots

. See the S1 Switch Programming Chart. For 

more feature information download (or request 
from RODIX) the FC-40 

Plus

 

 Advanced 

Application Note 24-210/24-211.  

 

10. STATUS LEDs 

When any of the inputs are active, the associated 
LED will turn ON.  When the RUN input conditions 
are met, the RUN LED will turn ON.  See section 6 
and the wiring diagram’s ON/OFF Control Guide 
for more information on how to satisfy the RUN 
conditions. 

 

 WARNING: 

Fuses should be replaced with a Bussman 

ABC or Littelfuse 3AB "Fast Acting" type or 

equivalent of manufacturer's original value. 

 

Mounting this control on a vibrating surface 
will void the warranty. 

 

 WARRANTY 
Rodix Control Products are Warranted to be 
free from defects in material and workmanship 
under normal use for a period of two years 
from date of shipment.  

For the full description of 

the warranty, terms, and software license, please 
contact the factory. 

 

For assistance installing or operating your Rodix 
Feeder Cube® please call the factory or visit our 
web site. Technical help is available to answer 
your questions and fax any needed information.  
To return a control for IN or OUT of warranty 
service, please ship it prepaid to: 

Rodix Inc.,  ATTN: Repair Department 

If under warranty, Rodix will repair or replace your 
control at no charge; If out of warranty, we will 
repair it and you will be billed for the repair 
charges (Time and Material) plus the return freight. 
 Quotes for repairs are available upon request.  A 
brief note describing the symptoms helps our 
technicians address the issue. 
 
Feeder Cube® is a registered TM of Rodix Inc. 
 

 
 
Banner

 is a registered Trademark of Banner 

Engineering Corp

,

 

 

TROUBLESHOOTING

 

For the control to run: The 

MAIN CONTROL DIAL

 

must be turned up or have over 4mA at the 4-
20mA input.  Either the DIRECT LED must be lit or 
both the INTERLOCK and EXT VOLTS LEDs must 
be on.  To light the DIRECT LED, connect a Run 
Jumper at TB2-6 & TB2-7. 

 To light the 

INTERLOCK LED, a Run Jumper must connect 
TB2-5 to TB2-6.  To illuminate the EXT VOLTS 
LED, TB2-11 & 12 needs a 10-30 VDC signal.  
See the “FC-40 Plus Troubleshooting Guide” for 
more information.  If the feeder only hums, flip the 
60/120 dip switch. 

 

DIMENSIONS 

 

 

 
 
 
 
 
 
 
 
 
 
 

RODIX, INC.

 

2316 23

rd

 Ave, Rockford, IL  61104 

Toll Free (800) 562-1868,  FAX (815) 316-4701

 

E-mail [email protected] 

www.rodix.com 

 

CE-41 Plus 24-211 10/16/2012 Page 3

S1 Programming Chart 

Program Description 

S1 Switch Positions 

 SW3 

SW4 

SW5 

Standard 

Program

0 0 0 

Linear Pot Taper

0-20mA 

option

0 1 0 

Empty Bowl Timer

Disable 

LVC

0 0 1 

2-Speed 

Operation

1 0 1 

30/40 Pulse Operation

Low Amplitude at “1” 

Содержание FEEDER CUBE CE-40 Plus Series

Страница 1: ... Communication Systems LLC Figure 1 Warning label installed on the control Warning There is hazardous voltage inside the control Disconnect power before opening the enclosure Only skilled or instructed persons should open the enclosure An electrically instructed person is a person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid...

Страница 2: ... SOFT Start trimpot clockwise for the gentlest start about a 6 sec ramp up to full output Turn the trimpot fully counter clockwise for no soft start 6 REMOTE OFF ON CONTROL A Run Jumper has been installed at the factory as shown on the enclosed wiring diagram Remote OFF ON operation of the FC 40 Plus Series Feeder Cube control can be configured to operate in one of the following ways A A low curre...

Страница 3: ...ing or operating your Rodix Feeder Cube please call the factory or visit our web site Technical help is available to answer your questions and fax any needed information To return a control for IN or OUT of warranty service please ship it prepaid to Rodix Inc ATTN Repair Department If under warranty Rodix will repair or replace your control at no charge If out of warranty we will repair it and you...

Страница 4: ... OUTPUT 10 INTERLOCK TERMINALS CE 90 PLUS SERIES FEEDER BOWL HOPPER INTERLOCK 11 9 6 CE 40 PLUS SERIES TERM STRIP TB 2 3 B 8 7 DC Voltage from PLC or CE 90 Plus C 12 10 9 LOW VOLTAGE INPUT SWITCHING INTERLOCK TERMINALS 8 CE 40 PLUS SERIES TERM STRIP TB 2 5 OFF ON CONTROL 11 10 30 VDC INPUT VOLTAGE 6 7 The common line is not fused in Europe The common line should be fused for North American machine...

Страница 5: ...ons for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drain wire should be tied to the chassis in the Rodix control The drain wire should be kept shorter than 2 Please see the enclosed picture Example of a drain wire termination 2 Never run I O signal wires...

Страница 6: ...sting was performed by Rodix at L F Research 12790 Route 76 Poplar Grove IL 61065 Machine Description Vibratory Feeder Control Makes CE 41 Plus CE 41H Plus CE 43 Plus CE 43H Plus CE 48 CE 48 Plus CE 48H Plus CE 49 Plus CE 49H Plus CE 91 Plus CE 91H Plus CE 91 2 Plus CE 91 2H Plus CE 91 3 Plus CE 91 3H Plus CE 93 Plus CE 93H Plus CE 98 Plus CE 98H Plus CE 98 2 Plus CE 98 2H Plus CE 98 3 Plus CE 98 ...

Страница 7: ...the standard 1 When the standard does apply When a 230V machine is not powered by a step down transformer there should not be a problem meeting this standard if all the vibratory feeders on one machine operate in the 100 Pulse full wave mode and the combined total amperage for the vibratory feeders is 15 Amps or less However it is harder to meet this standard in the 50 Pulse half wave mode The com...

Страница 8: ...p down transformer that is installed in a factory Thus the machine is powered by a higher voltage distribution system that is not directly connected to the 230V public low voltage system Because of this the machine is outside the scope of the standard1 A machine that is connected to 60Hz power is also outside the scope of the standard When the standard does apply The standard is applicable when a ...

Страница 9: ...gether if they always start and stop at the same time Actual testing may prove that the number of On Off cycles shown in the chart can nearly be doubled when the Soft Start pot is adjusted for a one second or longer soft start Amps rms at 230V Maximum On Off cycles permitted 16 1 On Off cycle per 6 minutes 15 1 On Off cycle per 4 5 minutes 14 1 On Off cycle per 3 minutes 13 1 On Off cycle per 3 mi...

Отзывы: