background image

 

 

CE-41 

Plus 

P/N 121-500-0746 

 

PRODUCT DESCRIPTION 

This device, P/N 121-500-0746, is used to control 
the vibration level a vibratory feeder.  The unit is 
powered from the incoming line connection. The 
unit has its own Master Control PC board.  The 
setup and operation is detailed in the following 
product literature. 

 

SPECIFICATIONS 

Line 

Voltage: 

  120 

VAC 

+/-10% 

Line 

Frequency: 

  50/60 

Hz 

Current:         

 

 

15A 

Output 

Voltage: 

  0-120 

VAC 

Handling & Transp. Temp. 

-40 – 60 

Operating Temp. 

 

0 – 40 

 

INSTALLATION 

The control is to be firmly mounted to a non-
vibrating surface.  The control is designed to 
withstand conditions equal to IP54.  Do not install 
the control in a more severe environment. 

 

Connections to external conduits or cords are to 
be made with hardware that is rated at IP54 or 
better.   

 

Refer to the electrical wiring diagram.  Line and 
load wiring is to be brought into the box via 
customer-drilled holes.  Use 2.5mm

2

 (#14 AWG) 

Mains supply wires or larger.  Use 2.5mm

2

 

(#14AWG) load wires or larger.  The Mains supply 
wires should be fused by the Customer at 15 amps 
or less.  After the wiring has been completed, 
verify the continuity of the ground bond connection 
to the control. 

 
 

This control is for industrial use.  Use in residential 
areas may cause interference, and in that case, 
special measures may have to be taken by the 
user regarding emissions. 
 

IMPORTANT - The vibratory feeder must be 
tuned to match the power line frequency of the 
destination country (50 or 60 Hz).  A feeder 
tuned to the wrong frequency will not feed 
parts.  The Rodix control operates on 50 or 60 
Hz. 

 

SAFETY 

When installing this control, a power supply 
disconnect device must be provided by the user.  
 A power plug/socket combination can be utilized 
for this purpose.  The plug and socket must have a 
breaking capacity of at least the amperage of the 
vibratory feeder(s). 

© 

2006 

Hazard Communication Systems, LLC  

Figure 1 – Warning label installed on the control 

 

Warning – There is hazardous voltage inside 
the control.  Disconnect power before opening 
the enclosure.

  Only skilled or instructed persons 

should open the enclosure. 

 

An electrically instructed person is a person 
adequately advised or supervised by an electrically 
skilled person to enable him or her to perceive 
risks and to avoid hazards which electricity can 
create.  

 

An Emergency stop device must be installed on 
the machine that incorporates the CE feeder 
control. 

 

When the machine is installed, verify the continuity 
of the protective bonding circuit (earth ground) to 
the control.   

PERIODIC INSPECTION AND 

FUNCTIONAL TESTING 

 

When the control is operating normally, the output 
can be smoothly adjusted from zero to maximum 
by the main control knob.  If part sensors are used, 
the control starts and stops automatically 
according to the time delay settings on the circuit 
board.  If soft-start is used, the output should start 
at zero and ramp up to the desired setting each 
time the control automatically starts.

 

The control should be kept reasonably free from 
dirt and contaminants that might inhibit proper 
cooling.  No other planned maintenance is 
necessary. 

 

MAINTENANCE 

Normally no maintenance is needed for this 
control.  If troubleshooting assistance is needed, 
either visit our web site at 

www.rodix.com

, call 

RODIX: (international call) 815-316-4700x322 or 
(USA) 1-800-562-1868x322,  FAX: 815-316-4701, 
or e-mail: 

[email protected]

 

SPARE PARTS 

 

Designation 

   Q   Rodix P/N   MFG P/N 

Control Card  

   1    123-293* 

Fuse 15A 250V    1    106-18* 

     Bussman 

 

 

 

 

     ABC15 

OR 

 

 

 

     Littlefuse 
     314015 

Fuse Holder         1     106-17  

     Littlefuse 

                                                          354901GY 
Triac 

 

   1    115-32* 

S1   (DPST)          1    104-80*   
Switch Boot 

   1    104-26* 

 

Term. End 

         264-301      Wago 

20A, 600V                                      264-301 
Terminal Single          264-321      Wago 
20A, 600V                                      264-321 
Terminal Dual             264-351      Wago 
20A, 600V                                      264-351 
Knob    

          122-01        APEM 

                                                      MPKES120B1/4 
*Recommended spare parts to keep in stock. 

 

© 2000, 2015 RODIX 

INC

.

 

CE-41 Plus 24-211 4/21/2014 Page 1

RODIX INC. 

FEEDER CUBE

 

CE-40

 

Plus Series

 

 

 

 

Содержание FEEDER CUBE CE-40 Plus Series

Страница 1: ... Communication Systems LLC Figure 1 Warning label installed on the control Warning There is hazardous voltage inside the control Disconnect power before opening the enclosure Only skilled or instructed persons should open the enclosure An electrically instructed person is a person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid...

Страница 2: ... SOFT Start trimpot clockwise for the gentlest start about a 6 sec ramp up to full output Turn the trimpot fully counter clockwise for no soft start 6 REMOTE OFF ON CONTROL A Run Jumper has been installed at the factory as shown on the enclosed wiring diagram Remote OFF ON operation of the FC 40 Plus Series Feeder Cube control can be configured to operate in one of the following ways A A low curre...

Страница 3: ...ing or operating your Rodix Feeder Cube please call the factory or visit our web site Technical help is available to answer your questions and fax any needed information To return a control for IN or OUT of warranty service please ship it prepaid to Rodix Inc ATTN Repair Department If under warranty Rodix will repair or replace your control at no charge If out of warranty we will repair it and you...

Страница 4: ... OUTPUT 10 INTERLOCK TERMINALS CE 90 PLUS SERIES FEEDER BOWL HOPPER INTERLOCK 11 9 6 CE 40 PLUS SERIES TERM STRIP TB 2 3 B 8 7 DC Voltage from PLC or CE 90 Plus C 12 10 9 LOW VOLTAGE INPUT SWITCHING INTERLOCK TERMINALS 8 CE 40 PLUS SERIES TERM STRIP TB 2 5 OFF ON CONTROL 11 10 30 VDC INPUT VOLTAGE 6 7 The common line is not fused in Europe The common line should be fused for North American machine...

Страница 5: ...ons for Electrical Noise 1 Use shielded wires for all I O Input Output signals The I O signals may include 4 20mA input Run input Sensor input 0 5VDC input Interlock input or AUX output The shield drain wire should be tied to the chassis in the Rodix control The drain wire should be kept shorter than 2 Please see the enclosed picture Example of a drain wire termination 2 Never run I O signal wires...

Страница 6: ...sting was performed by Rodix at L F Research 12790 Route 76 Poplar Grove IL 61065 Machine Description Vibratory Feeder Control Makes CE 41 Plus CE 41H Plus CE 43 Plus CE 43H Plus CE 48 CE 48 Plus CE 48H Plus CE 49 Plus CE 49H Plus CE 91 Plus CE 91H Plus CE 91 2 Plus CE 91 2H Plus CE 91 3 Plus CE 91 3H Plus CE 93 Plus CE 93H Plus CE 98 Plus CE 98H Plus CE 98 2 Plus CE 98 2H Plus CE 98 3 Plus CE 98 ...

Страница 7: ...the standard 1 When the standard does apply When a 230V machine is not powered by a step down transformer there should not be a problem meeting this standard if all the vibratory feeders on one machine operate in the 100 Pulse full wave mode and the combined total amperage for the vibratory feeders is 15 Amps or less However it is harder to meet this standard in the 50 Pulse half wave mode The com...

Страница 8: ...p down transformer that is installed in a factory Thus the machine is powered by a higher voltage distribution system that is not directly connected to the 230V public low voltage system Because of this the machine is outside the scope of the standard1 A machine that is connected to 60Hz power is also outside the scope of the standard When the standard does apply The standard is applicable when a ...

Страница 9: ...gether if they always start and stop at the same time Actual testing may prove that the number of On Off cycles shown in the chart can nearly be doubled when the Soft Start pot is adjusted for a one second or longer soft start Amps rms at 230V Maximum On Off cycles permitted 16 1 On Off cycle per 6 minutes 15 1 On Off cycle per 4 5 minutes 14 1 On Off cycle per 3 minutes 13 1 On Off cycle per 3 mi...

Отзывы: