: Saved with “Gen Param Save”
°
: Saved to a registration memory
¶
: Saved with “MIDI Param Save”
Tuning
The 538/i548 is set to standard concert pitch (A=
440.0Hz). However, it can easily and quickly be tuned
flat or sharp to match the pitch of another musical
instrument, such as a piano or harp.
In instruments augmented with pipes, the tuning
feature can be used to bring the electronics in tune
with the pipes or other acustic instruments. The 538/
i548 retains this setting when it is turned off.
The “Quick Menu” contains a “Master Tune” parameter
that allows you to specify whether and how the 538/
i548’s tuning can be changed.
(1) Press
[QUICK¥MENU]
.
(2) Use the Select knob to select “Console”.
(3) Confirm your choice by pressing
[QUICK¥MENU]
.
This takes you to a lower level with several options.
(4) Choose “Master Tuning” with the Select knob.
(5) Confirm your choice by pressing
[QUICK¥MENU]
.
(6) Select the desired option with the data entry
wheel.
(7) Save your setting if you wish to keep it.
See page 42, or proceed as follows: Press and hold
[SET]
+
[0]
for a few seconds.
(8) When finished, press and hold the
[ø¥EXIT]
piston to
return to the main page.
The current tuning setting appears in the display:
As there are now two parameters you can set, you
need to use the
data entry wheel
to change the
“
Tune
” setting, and the
Select knob
to change the
“
Transpose
” value (if necessary). These two
parameters can be changed without pressing
[QUICK¥MENU]
.
Tremulant controls
The first section of this manual (see page 19) described
how tremulants are activated, what stops they control
and how they are often used. Another impressive
feature of the 538/i548 are the
user-adjustable
Tremulants
. Although the tremulants are carefully set
at the factory and adjusted when the organ is voiced,
the rate and depth may be modified for each to meet a
particular musical need or suit an individual taste.
Adjusting tremulant settings
(1) Press
[QUICK¥MENU]
.
(2) Use the Select knob to select “Pipe Modeling”.
(3) Confirm your choice by pressing
[QUICK¥MENU]
.
This takes you to a lower level with several options.
Parameters Load
MIDI Parameters
USB Memory
Memory Set
USB Memory
General Parameters
USB Memory
DEMO SONGS
1 All Songs
2 New Song
43 …10
a. A voicing adjustment for the Rodgers Dealer/Installer. It is recommended not to change this setting.
Locked A= 440
The 538/i548 uses the tuning reference
for electronic instruments (A4= 440Hz)
and cannot be tuned (see below).
Adjustable
The pitch can be adjusted using the data
entry wheel or via an externally
connected MIDI device.
Manual Only
The pitch can be adjusted only with the
data entry wheel.
Rodgers 538_i548.book Page 33 Monday, February 4, 2008 9:02 AM
Содержание 538 insignia
Страница 1: ...o Classic Organ 538 i548 Owner s Manual...
Страница 58: ...58 Rodgers 538 i548 This page intentionally left blank...
Страница 59: ...Rodgers 538 i548 59 This page intentionally left blank...
Страница 64: ...64 Rodgers 538 i548 This page intentionally left blank...
Страница 66: ...66 Rodgers 538 i548 This page intentionally left blank...
Страница 68: ...68 Rodgers 538 i548 This page intentionally left blank...
Страница 69: ...Rodgers 538 i548 69...
Страница 70: ......
Страница 71: ......
Страница 72: ...602 00 0232 02 RES 652 07 Rodgers 538 i548 Owner s Manual E o 1905 811...