background image

RD10 HB Manual

Page 5

 

Note

Notes contain important information in connection with the directly related text or chapter.

Attention

You will find the Attention notes where data loss or display damage may be the result of non-compliance 

with this note.

Warning

Warnings inform you that personal damage or damage to the display or individual components thereof 

may be the consequence of carelessness or non-compliance with the respective warning.

Regulatory Information / Disclaimers

Installation and use of this display must be in strict accordance with the instructions included in the user 

manual provided with the product. Any changes or modifications made to this device that are not express-

ly approved by the manufacturer may void the user’s authority to operate the equipment.

The manufacturer is not responsible for any radio or television interference caused by unauthorized modi-

fication of this device or the substitution of the connecting cables and equipment other than specified by 

the manufacturer. It is the responsibility of the user to correct any interference caused by such unauthor-

ized modification, substitution or attachment. Manufacturer and its authorized resellers or distributors will 

assume no liability for any damage or violation of government regulations arising from failing to comply 

with these guidelines.

CE 

(with roda standard AC/DC converter)

EN 55022

 

(CISPR 22 ) Radio Frequency Interference

EN 55024

 

(EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6,EN61000-4-8, 

 

 

 

EN61000-4-11, EN61000-3-2, EN61000-3-3) Generic Immunity Standard)

LVD

   

EN 60950 ( IEC950 ) Product Safety, IEC 60950-1:2005

Power Safety

There are specific power requirements for this display:

• 

Only use an approved power adapter for this device.

• 

When unplugging the power cord, please be sure to disconnect it from the plug head.

• 

Make sure the socket and any other extension cord you use can support the total current load of 

all the connected devices.

• 

Before cleaning the computer make sure it is disconnected from any external power supply.

Содержание RD10 HB

Страница 1: ...Manual RD10 HB...

Страница 2: ...RD10 HB Manual Page 2 This page is intentionally left blank...

Страница 3: ...3 roda computer GmbH Landstrasse 6 77839 Lichtenau Baden Germany Phone 49 0 7227 9579 0 Fax 49 0 7227 9579 20 roda Service Center H llhorst Hankamp 2 32609 H llhorst Germany Phone 49 0 5744 944 470 Fa...

Страница 4: ...consequential damages resulting from any software defects Brand and product names mentioned in this publication may or may not be copyrights and or registered trademarks of their respective companies...

Страница 5: ...substitution of the connecting cables and equipment other than specified by the manufacturer It is the responsibility of the user to correct any interference caused by such unauthor ized modification...

Страница 6: ...the natural resources we encourage you to use the appropriate take back systems Those systems will re use or recycle most of the materials of your end life equipment in a sound way The cross bin symbo...

Страница 7: ...ng 16 2 Components and Operations 20 2 1 Location 20 2 2 Ruggedness 20 2 3 Power supply 20 2 4 Switching ON 20 2 5 Switching OFF 20 2 6 Display Panel 20 2 6 1 Brightness 21 2 7 Video signal inputs 21...

Страница 8: ...wing when using the AC DC adapter 25 2 18 1 2 Connection the AC DC adapter 25 2 18 1 3 AC DC adapter power LED 25 2 19 Picture in Picture PIP 26 2 19 1 Position and size of video overlay via RS232 26...

Страница 9: ...12 Brightness 40 5 Maintenance and Service 44 5 1 Cleaning 44 5 2 Calibration 44 5 3 Troubleshooting 45 5 3 1 General troubleshooting 45 5 3 1 1 Display problems 45 5 3 1 2 Sound problems 45 5 4 Servi...

Страница 10: ...RD10 HB Manual Page 10 This page is intentionally left blank...

Страница 11: ...C H A P T E R 1 Page 11 Introduction...

Страница 12: ...3 Specifications The following lists the standard scope of delivery for the display Please use this list to check the package contents for completeness Contact your dealer if one or more of the follo...

Страница 13: ...iew 1 2 Overview 1 2 1 Front view Figure 2 Front view Function keys F1 F7 MODE SET key Descrease brightness NVI key Increase brightness PiP key ON OFF button Power LED Heater LED Controll LEDs Functio...

Страница 14: ...n Function Type X1 MIL DC In 18V 32V DC SJT00RT 08 98PN014 X2 MIL Composite In PiP Signal input SJT00RT 10 35SN014 X3 MIL RD DVI RD DVI Signal input SJT00GS 12 35SN014 X4 MIL VGA RGB VGA RGB Signal in...

Страница 15: ...al Page 15 Overview 1 2 4 Right side view Figure 6 Right side view 1 2 5 Left side view Figure 7 Left side view Reduce volume Increase volume Please note The left and right side mounting holes are M6x...

Страница 16: ...he screw with appropriate force to not damage the threads 230 V AC operation Plug the line cable into an electrical outlet Plug the MIL plug of the AC DC adapter into the DC input of the display and t...

Страница 17: ...al Page 17 Please note You can find informations concerning power supply connectors for different countries in the annex The video signal during POST can vary and may depend on BIOS settings of the si...

Страница 18: ...RD10 HB Manual Page 18 This page is intentionally left blank...

Страница 19: ...Page 19 Components and Operation C H A P T E R 2...

Страница 20: ...o water or moisture Corrosion is accelerated if the system s power is ON Please take proper water resistant measures for cable connections The DC jack and cables are sealed and may be operated with wa...

Страница 21: ...decrease over time To recalibrate the touch screen run the calibration application see chapter 5 2 Calibration to improve the handling of the touch screen If the touch screen is operated via RD DVI ma...

Страница 22: ...via keystroke or wire contact trigger 2 12 1 Manual Invisible Mode To activate manual Invisible Mode simply press the brightness up and down buttons simultaneously To return to standard operating mode...

Страница 23: ...d m2 or else the goggles may be overpowered Even with subdued light the panel is not visible anymore to ne naked eye Also the function LEDs won t be visible as well We advise to perform the settings f...

Страница 24: ...ase note To reset the display to factory settings and to reverse all NVIS and Invisible Mode set tings push the MODE SET button and switch the display one Keep the MODE SET button for 2 more seconds a...

Страница 25: ...he C6 power inlet of the adapter Plug AC plug of the AC line into the wall outlet Attach the DC plug to the DC In connector of the RD10 HB turn the lock ring clockwise to secure it 2 18 1 3 AC DC adap...

Страница 26: ...eo overlay via RS232 You can operate the PIP function with the help of a HyperTerminal connection PIP function can be con figured signal source position size and state with a RS232 terminal connection...

Страница 27: ...es state Q q 7 Save settings All settings are saved S s 8 Faulty characters y Table 2 PIP overlay settings xpos Position X direction in pixel 0000 xxxx without comma ypos Position Y direction in pixel...

Страница 28: ...Components and Operations RD10 HB Manual Page 28 This page is intentionally left blank...

Страница 29: ...Page 29 Specifications C H A P T E R 3...

Страница 30: ...r 256 scales of gray Interfaces DC In VGA RGB RD DVI 2x USB 2 0 Frequency 60 Hz Power supply 18 32 V DC nominal 24 V DC max 30 W according to VG96916 T5 Operating temperature 32 C bis 60 C Storage tem...

Страница 31: ...ignal Function Type A VA 18 32 V DC Input B GND Ground Reference C Invisible Mode Wire Trigger 24 V DC Input Shell GND Ground Reference Table 5 Pinning X1 MIL DC In 3 3 2 X2 MIL Composite In Signal Fu...

Страница 32: ...I Signal Function Pin TDMS TX2 N Input 1 TDMS TX2 P Input 2 TMDS 2 GND Ground 3 PWRSW Output 4 DDC Clock Digital I O 5 DDC DATA Digital I O 6 TDMS TX1 N Input 7 TDMS TX1 P Input 8 TDMS 1 GND Ground 9...

Страница 33: ...Input 1 Red GND Ground 2 Green Input 3 Green GND Ground 4 Blue Input 5 Blue GND Ground 6 reserved Reserve 7 H Sync Input 8 Sync GND Ground 9 V Sync Input 10 Sync GND Ground 11 reserved Reserve 12 DDC...

Страница 34: ...ted 5 GND Ground 6 Table 9 Pinning X5 6 interfaces 3 4 Environmental ratings 3 4 1 IEC 60529 IP65 Protection Operating Storage Rating IP65 IP65 Table 10 IEC 60529 IP65 3 4 2 MIL STD 810F Item Descript...

Страница 35: ...onmental ratings Item Description Shock According MIL STD 810F Method 516 5 Procedure I 15 g 3 ms 100 shocks vertical half sine 100 g 0 5 ms 3 shocks per axis half sine 25 g 6 ms 3 shocks per axis hal...

Страница 36: ...Page 36 OSD Menu C H A P T E R 4...

Страница 37: ...lose itself automatically if there were no inputs for approx 20 sec onds To save adjusted values the Save Mode function must be executed Main menu and sub menu key functions Select sub menus left righ...

Страница 38: ...ze Table 13 OSD information 4 3 Saturation Function Description Saturation Set saturation Values 0 255 Value 0 black white Table 14 OSD saturation 4 4 OSD Position Function Description OSD H POS Chang...

Страница 39: ...OSD Gamma 4 7 Size Function Description PS_H_Size Change horizontal size PS PS_V_Size Chance vertical size PS PS_H_Pos Change horizontal position PS PS_V_Pos Change vertical position PS PS_H_Cap Chang...

Страница 40: ...ness Function Description Default Sharpness Sharpness on off off Table 21 OSD Sharpness 4 11 Contrast Function Description Default Contrast Set contrast Values 0 255 62 Table 22 OSD Contrast 4 12 Brig...

Страница 41: ...OSD Menu RD10 HB Manual Page 41 This page is intentionally left blank...

Страница 42: ...OSD Menu RD10 HB Manual Page 42 This page is intentionally left blank...

Страница 43: ...Page 43 Maintenance and Service C H A P T E R 5...

Страница 44: ...the device driver s calibration application If the roda driver suite is used the calibration application can be found in the start menu Click Start All Programs UDDP Calibrate and follow the instruct...

Страница 45: ...tings might turn off the display after a specific period of time Please make sure the brightness settings are not set too dark or bright Please make sure the backlight is not turned off Some pixels ar...

Страница 46: ...Service Center Hankamp 2 32609 H llhorst Phone 49 5744 944 470 Fax 49 5744 944 475 E Mail support roda computer com Service Mon Thu 8 30 am 12 30 pm 1 00 pm 4 30 pm Fri 8 30 am 12 30 pm 1 00 pm 3 00 p...

Страница 47: ...ter 5 5 Downloads 2 Fill out the service supply note completely 3 Describe the error or defect as precise as possible Defect only delays the repairs 4 If possible use the original packaging to send th...

Страница 48: ...Maintenance and Service RD10 HB Manual Page 48 This page is intentionally left blank...

Страница 49: ...Page 49 Annex A N N E X...

Страница 50: ...ertz unit I O Input Output IE Image Enhancing IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IP Ingress Protection kg Kilogram unit kHz Kilohertz...

Страница 51: ...power supply connectors for different countries Version Country region Technical data Europe 230V 50Hz 6A Switzerland 220V 50Hz 6A United Kingdom 240V 50Hz 6A Australia 240V 50Hz 6A North America 120V...

Страница 52: ...delivery 12 Figure 2 Front view 13 Figure 3 Rear side view 14 Figure 4 Connector panel 14 Figure 6 Right side view 15 Figure 7 Left side view 15 Figure 8 Upper side view 16 Figure 9 AC DC adapter 25...

Страница 53: ...33 Table 8 Pinning X4 interface 34 Table 9 Pinning X5 6 interfaces 34 Table 10 IEC 60529 IP65 34 Table 11 MIL STD 810F 35 Table 12 OSD Setup 37 Table 13 OSD information 38 Table 14 OSD saturation 38 T...

Отзывы: