Access Procedures
3-37
4.
Carefully disconnect the fiber-optic cables from the Gate Driver board
and carefully set them aside.
Important:
Minimum inside bend radius for fiber-optic cable is 25.4 mm (1
in.). Any bends with a shorter inside radius can permanently
damage the fiber-optic cable. Signal attenuation increases with
decreased inside bend radii.
5.
Remove the cables from X13, X14 and X15 sockets on the Gate Driver
board and carefully set them aside.
6.
Disconnect the DC Bus wiring from the Gate Driver board.
7.
Remove the cable-tie that secures the Power Module circuit board to the
Adapter board.
8.
Disconnect the output leads from the bottom of the Output Power
Module.
9.
Remove the Y bus bars.
!
ATTENTION:
Hazard of permanent eye damage exists when
using optical transmission equipment. This product emits intense
light and invisible radiation. Do not look into fiber-optic ports or
fiber-optic cable connectors.
Y Bus Bars