English-21
PowerFlex 40 Frames – Ratings are in kW and (HP)
IP20, NEMA/UL Type Open
Dimensions are in millimeters and (inches).
Weights are in kilograms and (pounds).
Communication, RFI Filter, IP 30/NEMA 1/UL Type 1 Option Kits
Drive Dimensions
Frame 120V AC – 1-Phase 240V AC – 1-Phase 240V AC – 3-Phase 480V AC – 3-Phase 600V AC – 3-Phase
B
0.4 (0.5)
0.75 (1.0)
1.1 (1.5)
0.4 (0.5)
0.75 (1.0)
1.5 (2.0)
0.4 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
3.7 (5.0)
0.4 (0.5)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
4.0 (5.0)
0.75 (1.0)
1.5 (2.0)
2.2 (3.0)
4.0 (5.0)
C
(1)
2.2 (3.0)
5.5 (7.5)
7.5 (10.0)
5.5 (7.5)
7.5 (10.0)
11.0 (15.0) 5.5 (7.5)
7.5 (10.0)
11.0 (15.0)
(1)
IP66, NEMA/UL Type 4X rated drives are not availble in Frame C drive ratings.
Fr
am
e
A
B
C
D
E
F
Ship
Weight
B
100
(3.94)
180
(7.09)
136
(5.35)
87
(3.43)
168
(6.61)
87.4
(3.44)
2.2
(4.9)
C
130
(5.1)
260
(10.2)
180
(7.1)
116
(4.57)
246
(9.7)
–
4.3
(9.5)
A
E
B
D
C
F
5.5 (0.22)
111.2
(4.38)
152.2
(5.99)
107.0 (4.21)
66.0 (2.60)
∅
22.2
(0.87)
∅
28.5
(1.12)
24.0 (0.94)
74.3
(2.93)
109.9
(4.33)
64.1 (2.52)
79.1 (3.11)
∅
22.2
(0.87)
∅
22.2
(0.87)
25.6 (1.01)
40.6 (1.60)
76.3
(3.00)
105.3
(4.15)
134.3
(5.29)
50.0 (1.97)
77.5 (3.05)
22.5 (0.89)
45.7 (1.80)
109.8
(4.32)
144.8
(5.70)
179.8
(7.08)
69.2 (2.72)
92.2 (3.63)
108.7 (4.28)
22.2 (0.87)
∅
22.2
(0.87)
∅
28.5
(1.12)
A
D
B
C
B Frame - 22-JBAB
C Frame - 22-JBAC
B Frame - 22-JBCB
(used with Comm Cover)
C Frame - 22-JBCC
(used with Comm Cover)
Dim
e
nsion
Option
B Frame
Drive
C Frame
Drive
A
Comm Cover
25 (0.98)
25 (0.98)
B
EMC Line Filter
50 (1.97)
60 (2.36)
C
EMC Line Filter
229 (9.02) 309 (12.17)
D
IP30/NEMA 1/UL
Type 1
33 (1.30)
60 (2.36)
IP30/NEMA 1/UL
Type 1 for Comm
Cover
64 (2.52)
60 (2.36)
Aotewell Ltd
www.aotewell.com Industry Automation
HongKong|UK|China [email protected]
+86-755-8660-6182