Rockwell PowerFlex 40 Скачать руководство пользователя страница 5

English-5

(3)

The AIC ratings of the Bulletin 140M Motor Protector Circuit Breakers may vary. See 

Bulletin 140M 

Motor Protection Circuit Breakers Application Ratings

.

(4)

Manual Self-Protected (Type E) Combination Motor Controller, UL listed for 208 Wye or Delta, 240 
Wye or Delta, 480Y/277 or 600Y/347. Not UL listed for use on 480V or 600V Delta/Delta, corner 
ground, or high-resistance ground systems.

(5)

When using a Manual Self-Protected (Type E) Combination Motor Controller, the drive must be 
installed in a ventilated or non-ventilated enclosure with the minimum volume specified in this 
column. Application specific thermal considerations may require a larger enclosure.

Input/Output Ratings

Approvals

Output Frequency: 0-400 Hz (Programmable)

Efficiency: 97.5% (Typical)

Digital Control Inputs (Input Current = 6mA)

Analog Control Inputs

SRC (Source) Mode:

18-24V = ON
0-6V = OFF

SNK (Sink) Mode:

0-6V = ON
18-24V = OFF

4-20mA Analog: 250 ohm input impedance
0-10V DC Analog: 100k ohm input impedance
External Pot: 1-10k ohms, 2 Watt minimum

Control Output

Programmable Output (form C relay)
Resistive Rating: 3.0A at 30V DC, 3.0A at 125V AC, 3.0A at 240V AC
Inductive Rating: 0.5A at 30V DC, 0.5A at 125V AC, 0.5A at 240V AC

Opto Outputs
30V DC, 50mA
Non-inductive

Analog Outputs (10 bit)
0-10V, 1k ohm Min.
4-20mA, 525 ohm Max.

Fuses and Circuit Breakers

Recommended Fuse Type: UL Class J, CC, T or Type BS88; 600V (550V) or equivalent.
Recommended Circuit Breakers: HMCP circuit breakers or equivalent.

Protective Features

Motor Protection: I

2

t overload protection - 150% for 60 Secs, 200% for 3 Secs (Provides Class 10 protection)

Overcurrent: 200% hardware limit, 300% instantaneous fault

Over Voltage:

100-120V AC Input – Trip occurs at 405V DC bus voltage (equivalent to 150V AC incoming line)
200-240V AC Input – Trip occurs at 405V DC bus voltage (equivalent to 290V AC incoming line)
380-460V AC Input – Trip occurs at 810V DC bus voltage (equivalent to 575V AC incoming line)
460-600V AC Input – Trip occurs at 1005V DC bus voltage (equivalent to 711V AC incoming line)

Under Voltage: 100-120V AC Input – Trip occurs at 210V DC bus voltage (equivalent to 75V AC incoming line)

200-240V AC Input – Trip occurs at 210V DC bus voltage (equivalent to 150V AC incoming line)
380-480V AC Input – Trip occurs at 390V DC bus voltage (equivalent to 275V AC incoming line)
460-600V AC Input – If P042 = 3 “High Voltage” trip occurs at 487V DC bus voltage (344V AC incoming line);

If P042 = 2 “Low Voltage” trip occurs at 390V DC bus voltage (275V AC incoming line)

Control Ride Through: Minimum ride through is 0.5 Secs - typical value 2 Secs

Faultless Power Ride Through: 100 milliseconds

Dynamic Braking

Internal brake IGBT included with all ratings except No Brake versions. Refer to Appendix B of the PowerFlex 40 User Manual 
for DB resistor ordering information.

UL

®

LIS

TED 966X

IND

CO N T E

Q

UL508C

UL

®

LIS

TED 966X

IND

CO N T E

Q

C

CSA 22.2

EMC Directive 89/336
 

LV: 

EN 50178, EN 60204

 

EMC:  EN 61800-3, EN 50081-1, EN 50082-2

Aotewell Ltd 

www.aotewell.com  Industry Automation

HongKong|UK|China [email protected]

+86-755-8660-6182

Содержание PowerFlex 40

Страница 1: ...Start At PowerUp is used in an inappropriate application Do not use this function without considering applicable local national and international codes standards regulations or industry guidelines ATTENTION Only qualified personnel familiar with adjustable frequency AC drives and associated machinery should plan or implement the installation start up and subsequent maintenance of the system Failur...

Страница 2: ...n Ambient Temperature Enclosure Rating Minimum Mounting Clearances Minimum Maximum 10 C 14 F 40 C 104 F IP20 NEMA UL Type Open Use Mounting Option A IP66 NEMA UL Type 4X Use Mounting Option A IP30 NEMA UL Type 1 1 1 Rating requires installation of the PowerFlex 40 IP 30 NEMA UL Type 1 option kit Use Mounting Option B 50 C 122 F IP20 NEMA UL Type Open Use Mounting Option B 25 mm 1 0 in 120 mm 4 7 i...

Страница 3: ...igures below 1 Turn the screw counterclockwise to loosen 2 Pull the jumper completely out of the drive chassis 3 Tighten the screw to keep it in place Jumper Location Important Tighten screw after jumper removal Phase to Ground MOV Removal Typical Grounding U T1 V T2 W T3 R L1 S L2 T L3 SHLD Disconnecting MOVs IP66 NEMA UL Type 4X IP20 NEMA UL Type Open R L1 S L2 T L3 1 2 3 4 Three Phase AC Input ...

Страница 4: ...4 7 5 10 0 33 0 180 264 16 3 34 6 60 140M G8E C45 100 C60 2069 305 380 480V AC 10 3 Phase Input 0 460V 3 Phase Output 22B D1P4x104 0 4 0 5 1 4 342 528 1 4 1 8 3 140M C2E B25 100 C07 1655 35 22B D2P3x104 0 75 1 0 2 3 342 528 2 3 3 2 6 140M C2E B40 100 C07 1655 50 22B D4P0x104 1 5 2 0 4 0 342 528 4 0 5 7 10 140M C2E B63 100 C09 1655 70 22B D6P0x104 2 2 3 0 6 0 342 528 5 9 7 5 15 140M C2E C10 100 C09...

Страница 5: ...reakers HMCP circuit breakers or equivalent Protective Features Motor Protection I 2 t overload protection 150 for 60 Secs 200 for 3 Secs Provides Class 10 protection Overcurrent 200 hardware limit 300 instantaneous fault Over Voltage 100 120V AC Input Trip occurs at 405V DC bus voltage equivalent to 150V AC incoming line 200 240V AC Input Trip occurs at 405V DC bus voltage equivalent to 290V AC i...

Страница 6: ...with a jumper between Terminals P2 and P1 Remove this jumper only when a DC Bus Inductor will be connected Drive will not power up without a jumper or inductor connected DC DC DC Bus Connection BR BR Dynamic Brake Resistor Connection Safety Ground PE 1 Important Terminal screws may become loose during shipment Ensure that all terminal screws are tightened to the recommended torque before applying ...

Страница 7: ...utral system the phase opposite the phase that is tapped in the middle to the neutral or earth is referred to as the stinger leg high leg red leg etc This leg should be identified throughout the system with red or orange tape on the wire at each connection point The stinger leg should be connected to the center Phase B on the reactor Refer to the PowerFlex 40 User Manual for specific line reactor ...

Страница 8: ...ast to stop without software interpretation Refer to the PowerFlex 40 User Manual for more information Control Terminal Block 04 05 06 07 01 02 03 08 09 11 12 13 14 15 16 17 18 19 Digital Common Digital Input 1 Digital Input 2 Digital Input 3 Stop 1 4 Start Run FWD 2 Direction Run REV Digital Input 4 Opto Common R1 R2 R3 Relay N O Relay Common Relay N C 24V DC 10V DC 0 10V or 10V Input Analog Comm...

Страница 9: ... Referenced to Digital Common Drive supplied power for digital inputs Maximum output current is 100mA 12 10V DC Referenced to Analog Common Drive supplied power for 0 10V external potentiometer Maximum output current is 15mA P038 13 10V In 2 Not Active For external 0 10V unipolar or 10V bipolar input supply input impedance 100k ohm or potentiometer wiper P038 A051 A054 A123 A132 14 Analog Common F...

Страница 10: ...r to the Drive 6 Apply AC power and control voltages to the drive 7 Familiarize yourself with the integral keypad features see next page before setting any Program Group parameters If a fault appears on power up refer to page 20 for an explanation of the fault code For complete troubleshooting information refer to the PowerFlex 40 User Manual Prepare For Drive Start Up ATTENTION Power must be appl...

Страница 11: ...l frequency is being adjusted its value is displayed and the Hertz LED flashes Any changes are saved immediately The display then returns to the Display Group parameter previously shown TIP By default the speed reference of an IP66 NEMA UL Type 4X rated drive is set to the internal frequency A069 Internal Freq TIP You can also change the speed reference by editing the parameter A069 Internal Freq ...

Страница 12: ...gh groups and parameters Increase decrease the value of a flashing digit Used to adjust internal frequency of IP66 NEMA UL Type 4X rated drives only when a Display Group parameter is shown and P038 Speed Reference is set to internal frequency A069 Internal Freq Enter Advance one step in programming menu Save a change to a parameter value Potentiometer 1 Used to control speed of drive Default is ac...

Страница 13: ... group 7 Press Enter or Sel to view the value of a parameter If you do not want to edit the value press Esc to return to the parameter number 8 Press Enter or Sel to enter program mode to edit the parameter value The right digit will flash and the Program LED will illuminate if the parameter can be edited 9 Press the Up Arrow or Down Arrow to change the parameter value If desired press Sel to move...

Страница 14: ...Analog In 0 10V 0 0 100 0 0 1 d021 Analog In 4 20mA 0 0 100 0 0 1 d022 Output Power 0 00 Drive Power 2 0 01 kW d023 Output Powr Fctr 0 0 180 0 deg 0 1 deg d024 Drive Temp 0 120 degC 1 degC d025 Counter Status 0 9999 1 d026 Timer Status 0 0 9999 Secs 0 1 Secs d028 Stp Logic Status 0 7 1 d029 Torque Current 0 00 Drive Amps 2 0 01 Amps Smart Start Up with Basic Program Group Parameters Stop drive bef...

Страница 15: ...s set to option 2 4 5 6 13 or 14 and the digital input is active A051 A052 A053 or A054 will override the speed reference commanded by this parameter Refer to Chapter 1 of the PowerFlex 40 User Manual for details P039 Accel Time 1 0 0 600 0 Secs 0 1 Secs 10 0 Secs Sets the rate of accel for all speed increases P040 Decel Time 1 0 1 600 0 Secs 0 1 Secs 10 0 Secs Sets the rate of decel for all speed...

Страница 16: ...g 6 Above Freq 7 Above Cur 8 Above DCVolt 9 Retries Exst 10 Above Anlg V 11 Logic In 1 12 Logic In 2 13 Logic 1 2 14 Logic 1 or 2 15 StpLogic Out 16 Timer Out 17 Counter Out 18 Above PF Ang 19 Anlg In Loss 20 ParamControl 21 NonRec Fault 22 EM Brk Cntrl 23 Above Fcmd 24 MsgControl for FRN 6 01 and later 0 A056 Relay Out Level 0 0 9999 0 1 0 0 A058 A061 Opto Out1 Sel Opto Out2 Sel 0 24 See A055 for...

Страница 17: ...A 0 kW 200 Drive Rated Power 0 20 mA 9 TstData 0 20 0 20 mA 0 mA 0000 65535 Hex FFFF 0 20 mA 10 OutFreq 4 20 4 20 mA 4 mA 0 Hz P035 Maximum Freq 0 20 mA 11 OutCurr 4 20 4 20 mA 4 mA 0 Amps 200 Drive Rated FLA 0 20 mA 12 OutVolt 4 20 4 20 mA 4 mA 0 Volts 120 Drive Rated Output Volts 0 20 mA 13 OutPowr 4 20 4 20 mA 4 mA 0 kW 200 Drive Rated Power 0 20 mA 14 TstData 4 20 4 20 mA 4 mA 0000 65535 Hex F...

Страница 18: ...p 0 0 Drive Amps 2 0 1 Amps 0 0 Disabled A099 Process Factor 0 1 999 9 0 1 30 0 A100 Fault Clear 0 2 0 Ready Idle 1 Reset Fault 2 Clear Buffer 0 A101 Program Lock 0 9999 0 Unlocked 1 Locked 0 A102 Testpoint Sel 400 FFFF 1 Hex 400 A103 Comm Data Rate 0 5 0 1200 1 2400 2 4800 3 9600 4 19 2K 5 38 4K 3 Power to drive must be cycled before any changes will affect drive operation A104 Comm Node Addr 1 2...

Страница 19: ...A Input 4 Comm Port 5 Setpnt Trim 6 0 10V Trim 7 4 20mA Trim 8 Comm Trim 0 A133 PID Feedback Sel 0 2 0 0 10V Input 1 4 20mA Input 2 Comm Port 0 A134 PID Prop Gain 0 00 99 99 0 01 0 01 A135 PID Integ Time 0 0 999 9 Secs 0 1 Secs 0 1 Secs A136 PID Diff Rate 0 00 99 99 1 Secs 0 01 1 Secs 0 01 1 Secs A137 PID Setpoint 0 0 100 0 0 1 0 0 A138 PID Deadband 0 0 10 0 0 1 0 0 A139 PID Preload 0 0 400 0 Hz 0...

Страница 20: ...nput Loss 1 An analog input is configured to fault on signal loss A signal loss has occurred F33 Auto Rstrt Tries Correct the cause of the fault and manually clear F38 Phase U to Gnd Check the wiring between the drive and motor Check motor for grounded phase Replace drive if fault cannot be cleared F39 Phase V to Gnd F40 Phase W to Gnd F41 Phase UV Short Check the motor and drive output terminal w...

Страница 21: ...09 136 5 35 87 3 43 168 6 61 87 4 3 44 2 2 4 9 C 130 5 1 260 10 2 180 7 1 116 4 57 246 9 7 4 3 9 5 A E B D C F 5 5 0 22 111 2 4 38 152 2 5 99 107 0 4 21 66 0 2 60 22 2 0 87 28 5 1 12 24 0 0 94 74 3 2 93 109 9 4 33 64 1 2 52 79 1 3 11 22 2 0 87 22 2 0 87 25 6 1 01 40 6 1 60 76 3 3 00 105 3 4 15 134 3 5 29 50 0 1 97 77 5 3 05 22 5 0 89 45 7 1 80 109 8 4 32 144 8 5 70 179 8 7 08 69 2 2 72 92 2 3 63 1...

Страница 22: ...rport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Power Control and Information Solutions Headquarters Publication 22B QS001G EN P June 2013 Supersedes December 2008 Copyright 2013 Rockwell Automation Inc All rights reserved IP66 NEMA Type UL Type 4X Dimensions are in millimeters and inches Weights are in kilograms and pounds Weight 5 2 11 5 165 6 50 146 5 75 6 5 0 26 270 10 63 253 9 96 82 ...

Отзывы: