3.
Press the Stop
button to clear the fault from the drive.
4.
Press the Esc
button until you see zero speed on the keypad display.
5.
Press the Select
button and use the Up
or Down
arrows until you see the Basic
Program group on the HIM display.
6.
Press the Enter or Sel button
to enter the Basic Program group. The right digit of the last viewed
parameter in that group will flash.
7.
Use the Up
or Down
arrows until you see P053. If you wait one (1) second, you will
notice that the HIM display scrolls with “P053 – Reset to Defaults”.
Note: Rather than pressing the Up
and Down
arrows to scroll through many
parameters in numerical order, you can also press Sel
button to move from digit to digit or bit to bit. The
digit or bit that you can change will flash.
8.
Once P053 is displayed, Press the Enter
button. You will see “0 - Ready/Idle” scroll across the
display. Press the Up
or Down
arrows until you see “2 – Factory Reset”.