25 of 136
4.
Find the following parameters in the list and add them to “ABC’s Group”:
Parameter 30 - Language
Parameter 43 - Minimum Freq
Parameter 31 - Motor NP Volts
Parameter 44 - Maximum Freq
Parameter 32 - Motor NP Hertz
Parameter 45 - Stop Mode
Parameter 33 - Motor OL Current
Parameter 46 - Start Source 1
Parameter 34 - Motor NP FLA
Parameter 47 - Speed Reference1
Parameter 35 - Motor NP Poles
Parameter 62 - DigIn TermBlk 02
Parameter 36 - Motor NP RPM
Parameter 63 - DigIn TermBlk 03
Parameter 37 - Motor NP Power
Parameter 64 - 2-Wire Mode
Parameter 39 - Torque Perf Mode
Parameter 65 - DigIn TermBlk 05
Parameter 40 - Autotune
Parameter 76 - Relay Out1 Sel
Parameter 41 - Accel Time 1
Parameter 81 - Relay Out2 Sel
Parameter 42 - Decel Time 1
Once the parameters have been added, click the “OK” button to download this CustomView group to the drive.
You can also select/highlight multiple parameters then click the “Add - >” button. This makes adding
parameters go a lot faster.
Содержание PowerFlex 525
Страница 8: ...8 of 136 About the PowerFlex 525 Demo Box ...
Страница 9: ...9 of 136 About the PowerFlex 755 DHQ Demo Box ...
Страница 12: ...12 of 136 Control and Navigation Keys ...
Страница 34: ...34 of 136 Relay Outputs changes required Opto Outputs Analog Outputs ...
Страница 126: ...126 of 136 Default Machine States Default Machine Commands ...
Страница 129: ...129 of 136 DMAT Device Status Rungs ...
Страница 130: ...130 of 136 DMAT Application Status Rungs ...
Страница 132: ...132 of 136 ...
Страница 136: ...136 of 136 Notes Publication CE DM253 EN P Sept 2015 Copyright 2014 Rockwell Automation Inc All rights reserved ...