92
Rockwell Automation Publication 20P-TG002B-EN-P - February 2018
Chapter 3
Part Replacement Procedures
8. For
regenerative drives only
, remove the bolts and washers that secure
the resistor wires and the connecting bus bars to the U and V Phase SCR
modules and remove the wires and bus bars.
9. For
non-regenerative drives only
, remove the bolts and washers that
secure the resistor wires and bus bars to the U and V Phase SCR
modules and remove the wires and bus bars.
10. Slide the U and V phase bus bars that pass through the AC current
transducers up and out of the drive.
8
Connecting bus bar
Connecting bus bar
Regenerative Drive
9
Non-Regenerative Drive
Содержание Allen-Bradley PowerFlex 20P
Страница 1: ...PowerFlex Digital DC Drive Frame B Catalog Numbers 20P Hardware Service Manual OriginalInstructions ...
Страница 8: ...8 Rockwell Automation Publication 20P TG002B EN P February 2018 Preface Notes ...
Страница 102: ...102 Rockwell Automation Publication 20P TG002B EN P February 2018 Chapter 3 Part Replacement Procedures Notes ...
Страница 128: ...128 Rockwell Automation Publication 20P TG002B EN P February 2018 Index Notes ...
Страница 129: ......