Chapter 4
Install and Operate the Junction Boxes
Configure the 2711T-JBIP65DM1 Junction Box
The 2711T-JBI65MI junction box with M12 On-Machine connections is
factory-wired. It is still shipped with the back plate removed, so you can configure
Box ID functionality or adjust the brightness of the illuminated push button on
the MobileView terminal before you mount the junction box to its back plate and
connect the M12 On-Machine connections.
Box ID Functionality
See
for where to find the Box ID address switches on the
junction box circuit board.
See
for how to configure Box ID functionality for your 2711T-JBI65MI
junction box.
Illuminated E-stop Button Brightness
See
for where to find the illuminated E-stop button on the
junction box circuit board.
See
for how to set the brightness of a second generation MobileView
terminal meant to attach to your 2711T-JBI65MI junction box.
Mount the IP65 Junction Box to Its Back Plate
To mount an IP65 junction box to its back plate, perform the following steps.
1.
If you temporarily mounted the IP65
junction box as detailed in
Mount the IP65 Junction Box on
page 41
, remove the junction box from
the screw bosses.
2.
Align the IP65 junction box with its
mounted back plate.
3.
Mount the junction box to its back plate with the six supplied screws.
Torque the six screws to 0.85…1.15 N•m (7.5…10.2 lb•in).
SHOCK HAZARD:
When the back plate is removed, the circuit board inside the
2711T-JBIP65DM1 junction box is sensitive to electrostatic discharge (ESD).
Use an anti-static wriststrap connected to the work surface, and properly grounded
tools and equipment.
IMPORTANT
To maintain a tight seal and the IP65 rating, verify that the junction
box is seated properly to the cover plate.
Содержание Allen-Bradley MobileView 2711T-VMBRACKET
Страница 6: ...6 Rockwell Automation Publication 2711T UM001E EN P March 2019 Table of Contents Notes ...
Страница 14: ...14 Rockwell Automation Publication 2711T UM001E EN P March 2019 Chapter 1 Features Notes ...
Страница 34: ...34 Rockwell Automation Publication 2711T UM001E EN P March 2019 Chapter 3 Operate theTerminal Notes ...
Страница 98: ...98 Rockwell Automation Publication 2711T UM001E EN P March 2019 Appendix A Specifications Notes ...
Страница 100: ...100 Rockwell Automation Publication 2711T UM001E EN P March 2019 Index Notes ...
Страница 101: ...Rockwell Automation Publication 2711T UM001E EN P March 2019 101 Index Notes ...
Страница 102: ...102 Rockwell Automation Publication 2711T UM001E EN P March 2019 Index Notes ...
Страница 103: ......