Communicating with Devices on a DH485 Link
9-3
The cable you use to connect the controller depends on the port you use on
the 1761-NET-AIC converter.
Step 2: Configure the DH-485 port of the controller
If you connect to this port:
Use this cable:
port 1
DB-9 RS-232, DTE connection
1747-CP3
or
1761-CBL-AC00
port 2
mini-DIN 8 RS-232 connection
1761-CBL-AP00
or
1761-CBL-PM02
3.
On the Serial Port tab, specify the appropriate communication settings.
The grayed out settings are selections
that do not apply to a DH-485 network.
1.
In RSLogix 5000 programming software, select the Controller folder. Right-click to select Properties.
2.
On the System Protocol tab, specify the appropriate serial communication configuration.
ahw0600.tif
ahw0601.tif
ah
w
0
602.tif