Create the Motor Status Screen
Chapter 6
3.
Double-click the object to
open the States editor.
The indicator is created with
four states. This example
uses only two.
4.
Delete rows 3 and 4.
5.
Edit state 1 (row 1).
a. Accept 0 as the Value.
b. Replace the MultiState0
text with MANUAL.
c. Select yellow as the
Background Color.
d. Select black as the Text
Color.
6.
Edit state 2 (row 2).
a. Accept 1 as the Value.
b. Replace the Multistate1
text with AUTO.
c. Select yellow as the
Background Color.
d. Select black as the Text
Color.
7.
Click OK to close editor.
8.
On the Appearance tab, set
the Border Style to Raised.
9.
On the Connections tab,
select Motor_AutoManual as
the Read tag.
10.
Resize the object to fit the
text for both states.
State 1
State 2
Содержание 2711C-F2M