Rockwell Automation Publication 750-TG101A-EN-P - June 2022
111
Chapter 5 Frame 6 Renewal Kits Installation
20. Remove the M4 x 8 mm slotted-Torx screw and metal tab from the M4
standoff on the power interface circuit board.
21. Remove the M4 standoff from the power interface circuit board.
22. Remove the five M4 x 14 mm slotted-Torx screws from the power
interface circuit board.
23. Remove the five M4 x 8 mm Torx screws that secure the power interface
circuit board to the standoffs on the chassis and remove the board.
23
M4 x 8 mm
T20 or F - 6.4 mm (0.25 in.)
2.6 N
•
m (23.0 lb
•
in)
22
M4 x 14 mm
T20 or F - 6.4 mm (0.25 in.)
2.6 N
•
m (23.0 lb
•
in)
20
M4 x 8 mm
T20 or F - 6.4 mm (0.25 in.)
2.6 N
•
m (23.0 lb
•
in)
21
M4 x 8 mm
T20 or F - 6.4 mm (0.25 in.)
2.6 N
•
m (23.0 lb
•
in)
20
22
21
23
22
23
23
23
Содержание 20G2
Страница 8: ...8 Rockwell Automation Publication 750 TG101A EN P June 2022 Notes ...
Страница 126: ...126 Rockwell Automation Publication 750 TG101A EN P June 2022 Chapter 5 Frame 6 Renewal Kits Installation Notes ...
Страница 194: ...194 Rockwell Automation Publication 750 TG101A EN P June 2022 Index Notes ...