57
MIDI Dump/Load
Any or all of the Taboo Twin presets may be dumped to a sequencer or another Taboo Twin via system exclu-
sive messages. The information exchanged when performing a MIDI Dump consists of parameter values, title
characters and controller assignment/limit information. When dumping a single preset into another Taboo Twin, the
dumped preset may be loaded into any preset location on the receiving Taboo Twin.
To dump a single Taboo Twin preset into another Taboo Twin:
Connect a standard MIDI cable from the M
IDI
O
UT
of the transmitting Taboo Twin to the M
IDI
I
N
on the receiving Taboo Twin.
Step 1
Step 2
With the M
ENU
button lit, turn the F
UNCTION
S
ELECT
controls on both the transmitting and
receiving Taboo Twins until "MIDI DUMP/LOAD" is displayed on each.
MIDI DUMP/LOAD
MIDI DUMP/LOAD
Step 3
Turn the P
ARAMETER
S
ELECT
control on each unit one step clockwise to "PR DUMP/LOAD".
1 PR DUMP/LOAD
1 PR DUMP/LOAD
Receiving Taboo Twin
Receiving Taboo Twin
Transmitting Taboo Twin
Transmitting Taboo Twin
IMPORTANT
ð
Do not allow a looping connection from the M
IDI
O
UT
/T
HRU
of the receiving Taboo Twin
back to the M
IDI
I
N
of the transmitting Taboo Twin.