10
1.1
Technical specifications
Parameter
Model
ARc 50V
ARc 50V
+Plus 150
ARc 65
ARc 65
+Plus 180
ARc 80
ARc 80
+Plus 180
Minimum - Maximum draught
11 -13 Pa
11-13 Pa
11-13 Pa
11-13 Pa
11-13 Pa
11 -13 Pa
Fuel consumption
2 kg/h
2,31 kg/h
2,60 kg/h
2,35 kg/h
2,8 kg/h
2,47 kg/h
Smoke mass flow rate
5,4 g/s
5,4 g/s
7,6 g/s
6,6 g/s
9,9 g/s
9,7 g/s
Efficiency
77,16 %
86,3%
77 %
85,3 %
77 %
85,3 %
Nominal output
6,3 kW
8,7 kW
8 kW
8,75 kW
10 kW
9 kW
Power range
5,5 - 9,5 kW
4 – 9 kW
5,5 – 10 kW
5,5 - 10 kW
6,5 - 11,5 kW
6,5 - 11,5 kW
Average CO concentration at 13% of O2
0,0564 %
0,048 %
0,099 %
0,062 %
0,099 %
0,062 %
NOx concentration at 13% of O2
98 mg/Nm3
102 mg/Nm
3
107 mg/Nm
3
106 mg/Nm3
107 mg/Nm3
106 mg/Nm3
OGC concentration at 13% of O2
53 mg/Nm3
51 mg/Nm
3
66 mg/Nm
3
51 mg/Nm3
66 mg/Nm3
51 mg/Nm3
Particle concentration at 13% of O2
23 mg/Nm3
13 mg/Nm
3
24 mg/Nm
3
23 mg/Nm3
24 mg/Nm3
23 mg/Nm3
Medium draft (trial)
11 Pa
8,4 Pa
11 Pa
8,4 Pa
11 Pa
8,6 Pa
Net weight
98 kg
114 kg
92 kg
108 kg
121 kg
138,9 kg
Maximum authorized load (fuel)
3 kg
2,5 kg
3 kg
4 kg
4 kg
4 kg
Reload height
200 mm
175 mm
175 mm
200 mm
200 mm
200 mm
Logs length
330 mm
330 mm
500 mm
450 mm
500 mm
500 mm
Minimum flue height
4000 mm
4000 mm
4000 mm
4000 mm
4000 mm
4000 mm
Ø Flue duct
150 mm
150 mm
180 mm
150 mm
180 mm
180 mm
Ø Air inlet
100 mm
100 mm
100 mm
100 mm
100 mm
100 mm
Ø Air outlet
120 mm
120 mm
120 mm
120 mm
120 mm
120 mm
Safety distances (back)
150 mm
150 mm
150 mm
150 mm
150 mm
150 mm
Safety distances (sides)
150 mm
150 mm
150 mm
150 mm
150 mm
150 mm
Safety distances (frontal)
1000 mm
1000 mm
1000 mm
1000 mm
1000 mm
1000 mm
Fireplace room ventilation (entry - exit)
450 cm
2
450 cm
2
450 cm
2
450 cm
2
450 cm
2
450 cm
2
Electrical wiring connection
Silicone hose 3*wire of 1.5 mm
2
Fan airflow (unit)
135 m
3
/h
Fan output (unit)
20 W
Minimum safety distance to the air outlets
250 mm
Average temperature of smoke
316º C
220,8ºC
322ºC
220,8ºC
313ºC
196,8ºC
Type of combustion
INTERMITENT
Flue liner
NOT SHARED
Fuel
NATURAL WOOD
Humidity fuel logs
12-20 % - two years under cover
Certification year
2016
2019
2022
2022
2021
2019
Certificate number
30-13474-T |
E-30-00014-18
1880-CPR-001-19 1880-CPR-018-
008-21
1880-CPR-008-
013-19
1880-CPR-018-
006-21
1880-CPR-001-19
Parameter
Model
ARc 70
ARc 70
+Plus 150
ARc 70A
ARc 70A
+Plus 150
ARc 70C
ARc 70C
+ Plus 150
Minimum - Maximum draught
11-13 Pa
11-13 Pa
11-13 Pa
11-13 Pa
11-13 Pa
11-13 Pa
Fuel consumption
2,66 kg /h
2,37 kg/h
2,66 kg /h
2,37 kg/h
2,66 kg /h
2,37 kg/h
Smoke mass flow rate
7,6 g/s
6,6 g/s
7,6 g/s
7,6 g/s
7,6 g/s
6,6 g/s
Efficiency
77%
85,3%
77%
85,3%
77%
85,3%
Nominal output
9.1 kW
8,8 kW
9,1 kW
8,8 kW
9.1 kW
8,8 kW
Power range
6 – 10.5 kW
6 – 10.5 kW
6 – 10.5 kW
6 – 10.5 kW
6 – 10.5 kW
6 – 10.5 kW
Average CO concentration at 13% of O
2
(%)
0,099 %
0,062 %
0,099%
0,062 %
0,099 %
0,062 %
NOx concentration at 13% of O2
:
(mg/Nm
3
)
107 mg/Nm
3
106 mg/Nm
3
91 mg/Nm3
106 mg/Nm
3
107 mg/Nm
3
106 mg/Nm
3
OGC concentration at 13% of O2
:
(mg/Nm
3
)
66 mg/Nm
3
51 mg/Nm
3
49 mg/Nm3
51 mg/Nm
3
66 mg/Nm
3
51 mg/Nm
3
Particle concentration at 13% of O2(mg/Nm
3
)
24 mg/Nm
3
22,9 mg/Nm
3
24 mg/Nm3
22,9 mg/Nm
3
24 mg/Nm
3
22,9 mg/Nm
3
Medium draft (trial)
13 Pa
8,4 Pa
13 Pa
8,4 Pa
13 Pa
8,4 Pa
Net weight
97 kg
113 kg
103 kg
119 kg
92 kg
108 kg
Maximum authorized load (fuel)
3 kg
3 kg
3 kg
3 kg
3 kg
3 kg
Reload height
175 mm
175 mm
175 mm
175 mm
175 mm
175 mm
Logs length
400 mm
400 mm
400 mm
400 mm
400 mm
400 mm
Minimum flue height
4000 mm
4000 mm
4000 mm
4000 mm
4000 mm
4000 mm
Ø Flue duct
150 mm
150 mm
150 mm
150 mm
150 mm
150 mm
Ø Air inlet
100 mm
100 mm
100 mm
100 mm
100 mm
100 mm
Ø Air outlet
120 mm
120 mm
120 mm
120 mm
120 mm
120 mm
Safety distances (back)
150 mm
150 mm
150 mm
150 mm
150 mm
150 mm
Safety distances (sides)
150 mm
150 mm
150 mm
150 mm
150 mm
150 mm
Safety distances (frontal)
1000 mm
1000 mm
1000 mm
1000 mm
1000 mm
1000 mm
Fireplace room ventilation (entry - exit)
450 cm
2
450 cm
2
450 cm
2
450 cm
2
450 cm
2
450 cm
2
Electrical wiring connection
Silicone hose 3*wire of 1.5 mm
2
Fan airflow (unit)
135 m
3
/h
Fan output (unit)
20 W
Minimum safety distance to the air outlets
250 mm
Average temperature of smoke
322º C
220,8ºC
322º C
220,8ºC
322º C
220,8ºC
Type of combustion
INTERMITENT
Flue liner
NOT SHARED
Fuel
NATURAL WOOD
Humidity fuel logs
12-20 % - two years under cover
Certification year
2021
2019
2021
2019
2021
2019
Certificate number
1880-CPR-018-
004-21
1880-CPR-001-19 1880-CPR-18-21 1880-CPR-001-19 1880-CPR-018-
004-21
1880-CPR-1-19
1. SPECIFICATIONS
Содержание ARc 100
Страница 47: ...46 II 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 48: ...47 III 1 2 ...
Страница 49: ...48 III 1 2 3 4 5 A ...
Страница 50: ...49 III B C A 1 A 2 A 3 A 4 ...
Страница 51: ...50 III A 5 A 6 A 7 A 8 B 1 B 2 ...
Страница 52: ...51 III B 3 B 4 B 5 B 6 B 7 C 1 ...
Страница 53: ...52 III C 2 Plus 150 Plus 180 C 2 C 2 C 3 C 4 C 5 ...
Страница 54: ...53 IV D 1 D 2 D 3 D 4 D 5 D 6 ...
Страница 55: ...54 IV D 7 D 8 D 9 D 10 D 11 D 12 ...
Страница 56: ...55 IV D 13 D 14 D 15 D 16 D 17 D 18 ...
Страница 57: ...56 IV D 19 D 20 D 21 D 22 D 23 D 24 ...
Страница 58: ...57 IV D 25 D 26 D 27 ...
Страница 64: ......