26
3 STORAGE
3.1 Unpacking
Check always the correspondence between documents and materials and the presence of eventual damages
due to transport.
Warning: Remove with care the packing and clearing all the dangerous elements (nails, splits,
etc…)
3.2 Handling
Blower
kg
45
97
65
159
85
250
105
400
125
610
145
1099
Warning : Do not use the holes in the flanges to lift the blower
3.3 Preservation
Keep the blower in a place protected against solar radiation and at following climatic conditions :
Temperature
from – 20°C to 40 °C
Relative humidity from 10% to 80%
If different climatic conditions are forecast contact ROBUSCHI.
Do not remove the nozzle protections and renew the preservation every 6 month or more frequently if
humidity is higher than 80% using antirust oil.
Parts
Anti-rust oil
Type
Trade
Shiny external parts
Rustia 27
Rust Ban 397
V-Produkt 9703
AGIP
ESSO
SHELL
Gear and bearings
Rustia C 100
Antiruggine MZ 110
Ensis Motor Oil 20
AGIP
ESSO
SHELL
Compression chamber
Rustia C 100
Antiruggine MZ 45
Ensis Motor Oil
AGIP
ESSO
SHELL
Warning : Use anti-rust oil with fire point over 200 °C
Warning : Dispose the used anti-rust oil in accordance with local regulations