First time start up.
Once the system is assembled, filled with water, and power is connected to the system a few basic
adjustments to the burner is required.
1. Fill the auger with pellets by force starting the auger either through the controller or directly via a
230V connection.
2. When the augur appears full, run for an additional 15 min. to
ensure correct weighing later.
3. Activate the 6 min. test run in the controller and collect the
dispensed pellets with a plastic bag.
4. Using a kitchen scale, weigh the pellets from the test run and enter the amount into the controller
under
"Auto calculation" Repeat again after 7 days!
5. Adjust minimum output as low as possible, typically 10% of the burner's rated output (i.e. if 20kW,
set to 2.00kW). If the chimney draft is high, adjust the minimum output up until you have a stable
flame at 10% power.
6. Once the burner is activated an ignition will be made. After approx. 20 minutes the burner will
reach a nominal output (100%). If necessary lock the burner output at 100%. Now you can perform
an evaluation as to whether the fan is providing suitable supply of air to the flame. If necessary,
adjust in the fan menu.
The flame at 100% should fill the entire width of the grate, have
redish spikes, and reach the opposite wall.
7. Lock the burner to 50% power. Wait 5 minutes for the flame to
stabilize. Again, assess fan performance in relation to the flame.
The flame at 50% should be approx. 10 cm out of the burner and is
yellowish in colour.
8. Lock the burner to 10% power. Wait 5 minutes for the flame to
stabilize. Assess fan performance in relationship to the flame.
The flame at 10% should be small and short.
The photo sensor reading may fluctuate, however, it should not have a
0 LUX reading for a period >10 sec. If the chimney draft is too high,
increase the minimum effect of the burner to increase flame size.
Содержание Black Star 10 Comfort
Страница 1: ...Black Star Pellet System...
Страница 5: ...Robus Energy Ltd 5 of 26 MCS 0001RE Issue 2 1 March 2014 Boiler Specifications...
Страница 14: ...Robus Energy Ltd 14 of 26 MCS 0001RE Issue 2 1 March 2014 Electrical Connections...
Страница 23: ...Robus Energy Ltd 23 of 26 MCS 0001RE Issue 2 1 March 2014 Trouble shooting...
Страница 26: ...Robus Energy Ltd 26 of 26 MCS 0001RE Issue 2 1 March 2014 CE declaration of conformity...