The Clean Air Act 1993 and Smoke Control Areas

 

 

 

The Robus Biopel range of boilers listed below has been recommended as suitable for use in 

smoke  control  areas.  The  recommended  fuel  for  the  boiler  is  6mm  or  8mm  diameter  wood 

pellets to EN 14961 Part 2 class A1 wood pellets only.

 

 

 

Robus Biopel 15

 

Robus Biopel 20

 

Robus Biopel 30

 

Robus Biopel 40

 

 

 

Under  the  Clean Air Act  local  authorities  may  declare  the  whole  or  part  of  the  district  of  the 

authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, 

from a furnace or from any fixed boiler if located in a designated smoke control area. It is also an 

offence to acquire an "unauthorised fuel" for use within a smoke control area unless it is used in 

an "exempt" appliance ("exempted" from the controls which generally apply in the smoke control 

area). 

 

The  Secretary  of  State  for  Environment,  Food  and  Rural  Affairs  has  powers  under  the  Act  to 

authorise  smokeless  fuels  or  exempt  appliances  for  use  in  smoke  control  areas  in  England.  In 

Scotland  and  Wales  this  power  rests  with  Ministers  in  the  devolved  administrations  for  those 

countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern 

Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas 

have been "authorised" in Regulations and that appliances used to burn solid fuel in those areas 

(other  than  "authorised"  fuels)  have  been  exempted  by  an  Order  made  and  signed  by  the 

Secretary of State or Minister in the devolved administrations.

 

 

 

Further  information  on  the  requirements  of  the  Clean  Air  Act  can  be  found  here 

http://

smokecontrol.defra.gov.uk/

 

 

 

 

Your local authority is responsible for implementing the Clean Air Act 1993 including designation 

and supervision of smoke control areas and you can contact them for details of Clean Air Act 

requirements”

 

Fuel and warranty

 

The Robus Biopel pellet boilers are designed for use with EN-plus A grade wood pellets only. The 

use of substandard fuels will compromise the efficiency, reduce the life span and invalidate the 

warranty of the appliance. 

 

What is EN-Plus?

 

 

 

EN-Plus  is  the  European  Quality  Standard  for  the  manufacture  and  supply  of  wood  pellets. 

Manufacturers and Distributors who have the EN-Plus standard have been certified as meeting the 

required quality standards and they are entitled to display the EN-Plus logo and their own unique 

License Number.

Содержание Biopel 15

Страница 1: ...Biopel Pellet Boiler Installation manual...

Страница 2: ...ibed here in this manual It is recommended to study the menus prior to initial start Save this manual so you always have it available when needed Page 3 Comments on the Manual Page 4 The Clean Air Act...

Страница 3: ......

Страница 4: ......

Страница 5: ...se countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have b...

Страница 6: ...uts as the seal between the boiler and the burner can leak over time 4 Make sure that the burner is horizontal and that all connections are tight Burner description The main parts of the burner are th...

Страница 7: ...ler for burner installation However the opposite flange on the boiler bust be always sealed For example if you choose left flange for burner connection make sure that right flange is properly sealed B...

Страница 8: ...le located on the top of the burner and secure with 2 x burner pipe screws Attach PVC tube on the burner pipe and from the other side on the external auger outlet You can cut the PVC tube if necessary...

Страница 9: ...nt ignition of the boiler and will prolong the life of the igniter The min buffer thermal store capacity should be 10 litres kW output eg 200 litres for Biopel 20 The load valve supplied with the boil...

Страница 10: ...and connection board are pre wired with simple plugs to allow for quick installation When using the Compact type hopper the connection board can be fixed to the sloping wall of the hopper near the bur...

Страница 11: ...is the boiler pump ROOM REGULATOR Room thermostat volt free Other connections for optional accessories are DHW PUMP Used to control a pump or 2 port valve for hot water production KOMPRESSOR Connecti...

Страница 12: ......

Страница 13: ...t is designed to offer the home owner and installer a series of simple menus to give full control of all boiler settings and parameters The controller has 3 levels of PIN protection in order to preven...

Страница 14: ...he same time o Summer mode sets the burner power to an half value To be specific Feed time max and Feed interval min is reduced to half Cleaning cleaning of the grate during PID modulation work o Acti...

Страница 15: ...rrection correction of fan speed 50 Power factor correction of burner power Changes values in Feedertimemax and Feeder interval min in range of 50 Example if you set 30 in Augercorrection 30 it means...

Страница 16: ...at the size in Kw is correct 5 Burner size changes values in Service settings shown below 6 Augersetup Ignition a Feed time for how long pellet auger supplies pellets on the burner grate b Fanspeed sp...

Страница 17: ......

Страница 18: ...for PID regulation is lower which means speed of the fan is decreased in all PID modulation range Power correction Power correction is responsible for changing number of pellets going on the grate Yo...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ...r is obligated to check the goods immediately upon receipt If the buyer declares that the delivery was inadequate or defective the customer must immediately and without delay make a written claim with...

Страница 23: ......

Отзывы: