1.1.1
Basic settings
-
Main screen
o
Display CH
o
Display service
-
CH temperature
– central heating temperature, which is maximum boiler flow temperature.
-
DHW temperature
– domestic hot water temperature, which is maximum temperature inside water
tank. DHW sensor must be connected into the Connection board.
-
Room temperature decrease
– works with room termostat RT10. Determines when should room
termostat start the boiler again after set temperature drop.
-
Operation mode
– operational mode for connected pumps.
o
Only CH – only CH pump works
o
DHW priority – DHW pump priority for hot water inside the tank
o
Pumps CH + DHW – both can work at the same time.
o
Summer mode – sets the burner power to an half value. To be specific - Feed time max and
Feed interval min is reduced to half.
-
Cleaning
– cleaning of the grate during PID (modulation) work
.
o
Activation – activate or deactivate cleaning function
o
Cleaning period – how often should fan clean the grate
o
Fan operation time – for how long time fan cleans the grate
o
Fan speed – speed of the fan during cleaning
-
Tray filled
– sets when you fill the with pellets. Then it will show you the real amount of pellets
inside the hopper.
-
Timetable
– timer for boiler operation. Set different temperatures for each hour per day.
o
Activate – activation of timer
o
Mode 1 (Mo-Su)
o
Mode 2 (Mo-Fr) (Sa-Su)
-
Set mode 1 – set working temperature for each day
-
Set mode 2 – set working temperature for weekends separatly
-
Alarm history
– history of alarms.