Service settings
Auger settup, Work,
Feeder
time max
Feeder
interval min
Plumber settings
Power correction
Service settings
Auger settup, Work,
Max fan
speed
Plumber settings
Fan correction
4.0 Fan correction
Fan correction is responsible for changing the flame size. You change fan speed only for max burner
power, but by changing this you basicly change all modulation range for fan speed.
What you change
You can adjust Max fan speed by changing % value in Fan correction. You can increase or decrease
this number which means you change full range of fan speed from minimum to maximum burner
power. If you decrease Max fan speed, the maximum limit for PID regulation is lower which means
speed of the fan is decreased in all PID modulation range.
Power correction
Power correction is responsible for changing number of pellets going on the grate. You change Feeder
time max and Feeder interval min in Service setup, which are values only for maximum burner power.
However by changing this value you basicly change the full modulation range. So it changes number
of pellets from min to maximum power.
What you change
You can adjust Feeder time max and Feeder interval min by adjusting % in Power correction. What
happends if:
•
you adjust minus value in Power correction: than you decrease number in Feeder time max
and increase Feeder interval min in the same time.
•
you adjust plus value in Power correction: than you increase number in Feeder time max and
decrease Feeder interval min inthe same time.