31
ROBOVENT •
DFS SERIES OWNER’S MANUAL
Marathon Motor Greasing Guidelines
Lubrication Procedure
1.
Stop motor. Disconnect and lock out of service.
2.
Remove contaminates from grease inlet area.
3.
Remove filler and drain plugs.
4.
Check filler and drain holes for blockage and clean as necessary.
5.
Add proper type of amount of grease. See the relubrication amounts table for volume
of grease required.
6.
Wipe off excess grease and replace filler and drain plugs.
7.
Motor is ready for operation.
Approved Greases
•
Chevron SRI #2
•
Rykon Premium #2
•
Exxon Polyrex EM
•
Texaco Polystar RB
Service Types
•
Seasonal Service:
The motor remains idle for a period of 6 months or more.
•
Standard Service:
Up to 16 hours of operation per day, indoors, 100° F max ambient temp.
•
Severe Service:
Greater than 16 hours of operation per day. Continuous operation under
high ambient temp (100 to 150° F), dirty moist locations, high vibration, heavy shock
loading or where shaft extension end is hot.
SECTION 1000
Motor Greasing Guide
Содержание FloorSaver Series
Страница 2: ......
Страница 29: ...ROBOVENT FUSION 4 5 SERIES OWNER S MANUAL 65 SECTION 1000 Motor Greasing Guide ...
Страница 38: ...ROBOVENT DFS SERIES OWNER S MANUAL ...
Страница 41: ...APPENDIX A ePad Electronic Programmable Controller Instruction Manual ...
Страница 51: ...APPENDIX B General Wiring Diagram ...
Страница 52: ...B 1 ROBOVENT DFS SERIES OWNER S MANUAL APPENDIX B General Wiring Diagram Single Blower ...
Страница 53: ...ROBOVENT DFS SERIES OWNER S MANUAL B 2 APPENDIX B General Wiring Diagram Double Blower ...
Страница 54: ......
Страница 55: ...APPENDIX C Parts List ...
Страница 58: ......
Страница 59: ......