Mode
Values
Description
Position Control Mode
Min Position Limit(52) ~ Max Position Limit(48) Initial Value : 0 ~ 4,095
Extended Position Control Mode
-1,048,575 ~ 1,048,575
-256[rev] ~ 256[rev]
Degree Conversion Constant
Description
0.088°/Value
1[rev] : 0 ~ 4,095
NOTE
: Profile Velocity(112) and
In Position Control Mode, Profile Velocity(112) and
are used to create a new
profile when Goal Position(116) is updated.
In Velocity Control Mode,
is used to create a new profile when Goal
Velocity(104) is updated.
NOTE
: When turning off the power supply or changing Operation Mode on Extended Position Control
Mode, the value of Present Position is reset to the absolute position value of single turn .
NOTE
:
represents 4 byte continuous range from -2,147,483,648 to
2,147,483,647 when Torque is turned off regardless of
.
However,
will be reset to an absolute position value of one full rotation in those
cases:
1. When
is changed to Position Control Mode,
reset to an absolute position value of a full rotation.
2. When torque is turned on in Position Control Mode,
absolute position value of one full rotation.
3. When turning off the power supply on Extended Position Control Mode,
be reset to an absolute position value of one full rotation.
value can be affected by
This value indicates DYNAMIXEL’s time.
Unit Value Range
Description
1 ms
0 ~ 32,767
The value resets to ‘0’ when it exceeds 32,767
Содержание Dynamixel X Series
Страница 27: ...3 1 Wiring through Back Case New XL430 W250 Released on 2018 3rd quarter ...
Страница 28: ...Old XL430 W250 This type has been discontinued ...