2F-85 & 2F-140 - Instruction Manual
The figure below illustrates the 2-Finger pigtail connector from the coupling (GRP-CPL-062 or AGC-CPL-XXX-002), the device
cable on the robot side (CBL-COM-2065-XX) and their associated pinout.
Fig. 3-10: Pinout of the 2-Finger pigtail and device cable.
If additional cable is used, suggested cable specifications are as follows:
Power supply, fusing:
l
minimum #22 AWG TEW, 300 V or 600 V
RS485 signal :
l
minimum #24 AWG TEW, 300 V or 600 V
l
A and B signals must be balanced at 120 Ohms
Single Gripper
Prior to any software installation or communication setup on the robot, connect the white, green, and bare wires to the proper
signal converter required (RS485-USB, RS85-RS232, Robotiq Universal Controller). Also connect the red (24V) and black (0V) wires
to the power supply.
Fig. 3-11: 2-Finger Adaptive Robot Gripper wiring to signal converter
For connection on the Robotiq Universal Controller, please refer to the Robotiq Universal Controller Manual.