RS-Ruby Users’ Manual
4
4 Interface
4.1 Power supply
The supply voltage should remain in the range of 9~32 VDC with utilization of
Interface-Box. The recommend supply voltage is 19 VDC. The power consumption is
about 45 W.
4.2 Data Output interface of LiDAR
The data output access of RS-Ruby is physically protected by an aviation terminal
connector. From the LiDAR to the aviation connector the cable length is 1 meter. The pins
of the aviation terminal connector are defined as follow:
PIN
Wire Color
Function
1
Black/Brown
GROUND
2
Black
Gigabit network differential signal
3
Brown
Gigabit network differential signal
4
Black/Green
GROUND
5
Red
Gigabit network differential signal
6
Orange
Gigabit network differential signal
7
White/Orange
GROUND
8
Yellow
Gigabit network differential signal
9
Green
Gigabit network differential signal
10
White/Purple
GROUND
11
Blue
Gigabit network differential signal
12
Purple
Gigabit network differential signal
13
Yellow/Brown
GROUND
14
Black/Red
GROUND
15
Black/Orange
PWR
16
Black/Yellow
PWR
17
White/Black
PWR
18
White/Brown
PWR
19
White/Red
PWR
20
White/Yellow
PWR
21
White/Green
Reserved serial signal
22
White/Blue
Reserved serial signal
23
Yellow/Green
GPS_PULSE