![RoboSense RS-Bpearl Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/robosense/rs-bpearl/rs-bpearl_user-manual_1471059030.webp)
25
RS-Bpearl User Manual
Time_offset is:
Formal for Calculation of Time_offset from Channel 1 to channel 8 and from channel 17 to
channel 24:
Time_offset = 55.52 * (sequence_index - 1) + 2.56 * mod((data_index – 1) , 16) + 1.28 *
floor((data_index-1) / 16)
Formal for Calculation of Time_offset from Channel 9 to channel 16 and from channel 25
to channel 32
:
Time_offset = 55.52 * (sequence_index - 1) + 2.56 * mod((data_index – 1) , 16) + 1.28 *
floor((data_index-1) / 16) + 5.2
To calculate the exact point time, add the Time_Offset to the timestamp
:
Exact_point _time = Tim Time_offset
Содержание RS-Bpearl
Страница 1: ...RS Bpearl User Manual...
Страница 11: ...6 RS Bpearl User Manual 4 4 Connection of Interface Box Figure 4 Diagram of Interface Box Connection...
Страница 13: ...8 RS Bpearl User Manual Figure 5 Single Return MSOP...
Страница 26: ...21 RS Bpearl User Manual 31 7 9375 0 32 2 3125 0 Every sequence of 32 laser firings consumes 55 5us...
Страница 48: ...43 RS Bpearl User Manual Figure C 21 Fault Diagnosis Dialogue...
Страница 52: ...47 RS Bpearl User Manual Appendix E Dimension Figure E 1 Dimension Drawing of RS LiDAR Bpearl...