SPIROR HP - DR
Every 2000
hours
Rotating ring
belt
General
inspection
Check for wear
and, if
necessary,
replace Contact
the Servicing
Department.
-
Every 2000
hours
Rotating ring
belt
General
inspection
Tension
adjustment
See "Rotating
Ring Belt -
Adjustment".
Every 2000
hours
Product infeed
units chain
General
inspection
Lubrication
See “Lubrication
point diagram”.
Every 2000
hours
Product infeed
units chain
General
inspection
Tension
adjustment
See "Product Feed
Line Chain -
Adjustment".
Every 2000
hours
Safety devices
Efficiency
control
Replace the
damaged
components
-
Every 2000
hours
Filter reduction
unit
Condensation
control
Condensation
discharging
See “Condensate
drainage”.
Every 2000
hours
Filter reduction
unit
Cleaning
Clean with a
blast of air and
alcohol
See "Filter
cleaning".
Every 5000
hours
Cutting blade
Efficiency
control
Change
See “Film cutting
blade
replacement”.
Every 5000
hours
Rotating ring
belt
Efficiency
control
Change
See "Rotating
ring belt
replacement".
|
Note
The maintenance periods relate to
8
-hour working days.
English
80/95
Содержание SPIROR DR
Страница 16: ...SPIROR HP DR SPIROR HP SPIROR HP 300 SPIROR HP 400 600 English 16 95 ...
Страница 17: ...SPIROR HP DR SPIROR HP 900 SPIROR DR SPIROR DR 400 600 Optional English 17 95 ...
Страница 18: ...SPIROR HP DR SPIROR DR 400 600 SPIROR DR 900 Optional SPIROR DR 900 English 18 95 ...
Страница 38: ...SPIROR HP DR SPIROR HP 600 SPIROR HP 900 English 38 95 ...
Страница 39: ...SPIROR HP DR SPIROR DR 400 SPIROR DR 600 English 39 95 ...