ENG
REPLACEMENT INFORMATION
114
9.3. REPLACING THE ROTARY TABLE ROLLERS
1.
Loosen the screws (A).
2.
Fit the eyebolts (B) on the rotary table (C).
3.
Lift the table and place it on the ground.
4.
Replace the rollers (D).
5.
Reposition the table on the base and fasten it with the screws.
Important
Should it not be possible to lift the rotary table using the eyebolts as indicated in point 2, position the
support (E) and screw it into the rotary table central seat using the screws (F).
Lift the rotary table using the fork lifting device.