121
6.
E
xtern
al Dim
ensi
on
s
6.13 Dust-proof/splash-proof specification, standard specification
RCP6W-RA6R Top Side-Mounted (Model: MT)
Must be 100 or more.
(Ø3
2)
27.5
168.5 (Same for those with brake)
R
41.5
A
L
(21.3)
Ø4
6h
9
2.5
35
63.5
17
M10×1.25
S.E.
M.E.
Greasing port (Ø5 hole)
(Same for opposite side)
Air intake/exhaust port
Applicable tube O.D.: Ø6
Mounting surface can be changed
Fitting rotation range
Grease fitting (for rod)
Mounting surface can be changed
AC(2,5,10,15)
*1
17
*2
Actuator cable
(robot cable)
Actuator/controller connection cable
Grease discharge hole
(top and side)
45
45
61
57
58
(1
)
58
30
12
0
4-M6 Depth 12
(16.2)
5
32
45
45
4-M6 Depth 12
9.
5
2.
5
5.
3 9
6.3
10.3
32
32
5
91
Cable exit direction (option)
CJL
Left Side
CJR
Right Side
CJO
Outside
19.5
(1
4.
1)
10
Enclosed square nut
Scale 1:1
M6
5
3
3
Stroke
Ø2
5
(ro
d
O.
D.
)
20
22
9.5
M.E.
Home
14
14
25
The angle of the width
across flat is undefined
P
6
17
(1
9.
6)
Enclosed hexagonal nut
Scale 1:1
M10×1.25
Detailed view P
Scale 1:1
M.E. : Mechanical End
S.E. : Stroke End
*1 Make sure that the total length of the actuator cable and actuator/controller connection cable is 20m or less.
*2 The cable relay section within the dotted line is not splash-proof.
Stroke
L
A
R
Mass [kg]
W/o
Brake
With
Brake
50
200
172.5
31.5
2.8
2.9
100
250
222.5
81.5
3.2
3.3
150
300
272.5 131.5
3.6
3.7
200
350
322.5 181.5
3.9
4.0
250
400
372.5 231.5
4.3
4.4
300
450
422.5 281.5
4.7
4.8